4 Image Acquisition
4.2.5
Acquisition Control Output Signals
The acquisition control block has the following output signals:
Acquisition Trigger Wait
An asserted acquisition trigger wait indicates, that the acquisition
control is waiting for an acquisition start trigger (see Section 4.2.3).
Acquisition Active
Acquisition active is a status signal, which is asserted, when the acquisition
has been started and deasserted, when the acquisition is stopped.
Acquisition Start
The acquisition start is an event, which is generated, when the acquisition is
started.
Acquisition End
The acquisition end is an event, which is generated, when the acquisition is
stopped.
Acquisition Trigger
The acquisition trigger is an event, which is generated, when the
acquisition is started by the acquisition start trigger (see Section 4.2.3).
Acquisition trigger wait and acquisition active status signal are routed to the I/O control block
and can there be selected for output on the physical output line or on one of the available leds
(see Chapter 6). Acquisition start, acquisition end and acquisition trigger event can be used to
trigger or to control other function in the camera, like counter or timer.
4.3
Frame Control
F
r a m
e C o n t r o l
F r a m
e S t a r t T r i g g e r
F r a m
e B u r s t S t a r t T r i g g e r
F r a m
e T r i g g e r W
a i t
F r a m
e S t a r t
F r a m
e E n d
F r a m
e B u r s t E n d T r i g g e r
F r a m
e T r i g g e r
F r a m
e A c t i v e
F r a m
e B u r s t S t a r t
F r a m
e B u r s t E n d
Figure 4.5: Frame Control Block
As soon as the acquisition is active the camera is ready to capture frames, which is controlled by
the frame control block. The behaviour depends on the frame start trigger, frame burst start
trigger and frame burst end trigger configuration.
4.3.1
Frame Start Trigger
The frame start trigger can be used to start a single frame capture. The main property of this
trigger is the trigger mode. It can be set to on or off:
Frame Start Trigger Mode = on
As soon as a frame start trigger has been received, a capture of
one frame will be started and the frame status goes to "Frame Active". Once one frame
has been processed, that camera status goes to "Frame Trigger Wait" again. The camera
is ready to process frame start triggers, when the acquisition is active, showed by the
"Acquisition Active" status, and when the "Frame Trigger Wait" status is asserted.
Frame Start Trigger Mode = off
The frame start triggers are ignored.
24 of 121
MAN076 09/2017 V1.0
Содержание MV3-D640I-M01-144-CL
Страница 10: ...1 Preface 10 of 121 MAN076 09 2017 V1 0...
Страница 34: ...4 Image Acquisition 34 of 121 MAN076 09 2017 V1 0...
Страница 46: ...6 I O Control 46 of 121 MAN076 09 2017 V1 0...
Страница 76: ...9 Pixel Data Processing 76 of 121 MAN076 09 2017 V1 0...
Страница 78: ...10 Thermoelectric Cooler TEC 78 of 121 MAN076 09 2017 V1 0...
Страница 82: ...11 Precautions 82 of 121 MAN076 09 2017 V1 0...
Страница 94: ...12 Hardware Interface 94 of 121 MAN076 09 2017 V1 0...
Страница 100: ...14 Troubleshooting 100 of 121 MAN076 09 2017 V1 0...
Страница 106: ...17 Support and Repair 106 of 121 MAN076 09 2017 V1 0...
Страница 108: ...18 References 108 of 121 MAN076 09 2017 V1 0...
Страница 112: ...A Pinouts 112 of 121 MAN076 09 2017 V1 0...
Страница 120: ...C Use Cases 120 of 121 MAN076 09 2017 V1 0...
Страница 121: ...D Document Revision History Revision Date Changes 1 0 July 2017 First version MAN076 09 2017 V1 0 121 of 121...