Timed Exposure Mode Camera Timing
Fig. B.1 shows a timing example, when the camera capture frames with rising edges on the
camera ISO_IN input. The external signal, which is fed into the cameras ISO_IN input is isolated
by an opto-isolator. This signal is delayed by t
iso
−
in
before it reaches the FPGA input "Line In".
The "Line In" signal is synchronized to the FPGA clock domain and the rising edge is detected.
There is a clock uncertainty because of the synchronization logic which is shown by the
t
input
−
jitter
value. The input pulse can be delayed by the trigger delay feature (see Section 4.6.6)
according to the requirement of the application. Finally the exposure time cycle starts after an
offset delay t
exposure
−
offset
.
When the application needs a strobe pulse together with the image acquisition, the internal
line in pulse can also be used to start one of the timer. After the timer delay t
timer
−
delay
the
timer duration t
timer
−
duraton
is started which is shown by the timer active signal (see Section
5.2). The timer active signal needs to be selected to output it on "Line Out" (see Section 6.2),
which has a fix delay of t
lineout
−
offset
. The "Line Out" is isolated by an opto-isolator from the
camera electronics which leads to an additional delay of t
iso
−
out
.
The maximum exposure offset value t
exposure
−
offset
is up to the read out time of
one image row, when a new exposure starts during read out of the previous
image. In this case, the start of the exposure is postponed to the start of the
next image row read out.
Table B.1 gives an overview of the minimum and maximum values of the timing parameters.
Timing Parameter
Min Value
Max Value
t
iso
−
in
5
µ
s
18
µ
s
t
input
−
jitter
83.3 ns
111.1 ns
t
pulse
−
delay
0 s
0.466 s
t
exposure
−
offset
250 ns
280 ns
1)
/ ( time of 1 image row 6.4
µ
s)
2)
t
exposure
333 ns
0.466 s
t
timer
−
delay
0 s
119 s
t
timer
−
duration
0 s
119 s
t
lineout
−
offset
111 ns
111 ns
t
iso
−
out
5
µ
s
18
µ
s
Table B.1: Camera timing parameter values of the timed exposure mode (Footnotes:
1)
New exposure starts
after readout of previous image;
2)
New exposure starts during readout of previous image)
MAN076 09/2017 V1.0
113 of 121
Содержание MV3-D640I-M01-144-CL
Страница 10: ...1 Preface 10 of 121 MAN076 09 2017 V1 0...
Страница 34: ...4 Image Acquisition 34 of 121 MAN076 09 2017 V1 0...
Страница 46: ...6 I O Control 46 of 121 MAN076 09 2017 V1 0...
Страница 76: ...9 Pixel Data Processing 76 of 121 MAN076 09 2017 V1 0...
Страница 78: ...10 Thermoelectric Cooler TEC 78 of 121 MAN076 09 2017 V1 0...
Страница 82: ...11 Precautions 82 of 121 MAN076 09 2017 V1 0...
Страница 94: ...12 Hardware Interface 94 of 121 MAN076 09 2017 V1 0...
Страница 100: ...14 Troubleshooting 100 of 121 MAN076 09 2017 V1 0...
Страница 106: ...17 Support and Repair 106 of 121 MAN076 09 2017 V1 0...
Страница 108: ...18 References 108 of 121 MAN076 09 2017 V1 0...
Страница 112: ...A Pinouts 112 of 121 MAN076 09 2017 V1 0...
Страница 120: ...C Use Cases 120 of 121 MAN076 09 2017 V1 0...
Страница 121: ...D Document Revision History Revision Date Changes 1 0 July 2017 First version MAN076 09 2017 V1 0 121 of 121...