C Use Cases
C.3.1
Counter Reset
A counter needs to be reset in order to be activated after configuration. This can be done by
the software reset command
CounterReset
or by an external reset source, which can be selected
by the parameter
CounterResetSource
of the corresponding counter. Furthermore for each
counter there is an automatically counter reset at acquisition start feature available:
CounterAcquisitionStartReset
. If it is set to
True
, the corresponding counter is reset when an
acquisition start command is applied. Depending on the application, it might be necessary, that
the current counter value must not be reset at acquisition start. In this case the parameter
CounterAcquisitionStartReset
must be set to
False
for the corresponding counter and the user
must execute the parameter
CounterReset
manually for a first counter start.
C.3.2
Image Counter
Any of the four available counters can be used as an image counter. The following
configuration procedure must be applied:
1.
Select one of the four available counters by setting of the
CounterSelector
to
Counter0
,
Counter1
,
Counter2
or
Counter3
.
2.
Select the corresponding counter event source by the parameter
CounterEventSource
. Any
signal source, which is generated with every frame, can be select. For instances
FrameStart
or
ExposureStart
can be selected.
3.
Parameter
TimerTriggerActivation
can be ignored. This configuration is only necessary,
when
Line0
input is selected as a trigger source.
4.
All other counter parameter must be left in default state (Both the
CounterResetSource
and
CounterTriggerSource
must be set to
Off
)
5.
The counter needs to be reset (see C.3.1).
C.3.3
Real Time Counter
Any of the four available counters can be used as a real time counter. The following
configuration procedure must be applied:
1.
Select one of the four available counters by setting of the
CounterSelector
to
Counter0
,
Counter1
,
Counter2
or
Counter3
.
2.
Set the parameter
CounterEventSource
to
TimeStampTick
.
3.
Parameter
TimerTriggerActivation
can be ignored. This configuration is only necessary,
when
Line0
input is selected as a trigger source.
4.
Configure the time stamp tick value
CounterTimeStampTickValue
. For instances a value of 1
µ
s generates an event every 1
µ
s.
5.
All other counter parameter must be left in default state (Both the
CounterResetSource
and
CounterTriggerSource
must be set to
Off
)
6.
The counter needs to be reset (see C.3.1).
C.3.4
Missed Trigger Counter
For monitoring purposes it might be necessary to detect an overtriggering condition. It means,
that not all applied triggers can be processed by the camera. This can be done by setting up of
a missed trigger counter. Any of the four available counters can be used as a missed trigger
counter. The following configuration procedure must be applied:
118 of 121
MAN076 09/2017 V1.0
Содержание MV3-D640I-M01-144-CL
Страница 10: ...1 Preface 10 of 121 MAN076 09 2017 V1 0...
Страница 34: ...4 Image Acquisition 34 of 121 MAN076 09 2017 V1 0...
Страница 46: ...6 I O Control 46 of 121 MAN076 09 2017 V1 0...
Страница 76: ...9 Pixel Data Processing 76 of 121 MAN076 09 2017 V1 0...
Страница 78: ...10 Thermoelectric Cooler TEC 78 of 121 MAN076 09 2017 V1 0...
Страница 82: ...11 Precautions 82 of 121 MAN076 09 2017 V1 0...
Страница 94: ...12 Hardware Interface 94 of 121 MAN076 09 2017 V1 0...
Страница 100: ...14 Troubleshooting 100 of 121 MAN076 09 2017 V1 0...
Страница 106: ...17 Support and Repair 106 of 121 MAN076 09 2017 V1 0...
Страница 108: ...18 References 108 of 121 MAN076 09 2017 V1 0...
Страница 112: ...A Pinouts 112 of 121 MAN076 09 2017 V1 0...
Страница 120: ...C Use Cases 120 of 121 MAN076 09 2017 V1 0...
Страница 121: ...D Document Revision History Revision Date Changes 1 0 July 2017 First version MAN076 09 2017 V1 0 121 of 121...