5 Functionality
Figure 5.27: LFSR (linear feedback shift register) test image
non-flat histogram (Fig. 5.29) indicates problems, that may be caused either by the cable, by
the connectors or by the frame grabber.
A possible origin of failure message can be caused by the CameraLink
®
cable
which exceeds the maximum length. The maximal cable length depends on the
frequency of the pixel clock. At a pixel clock of 80 MHz, a length of 8 m can be
achieved with a good cable. Also, CameraLink
®
cables may suffer either from
stress due to wrong installation or from severe electromagnetic interference.
.
46