![Photon Focus CameraLink MV1-D1280 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/photon-focus/cameralink-mv1-d1280/cameralink-mv1-d1280_user-manual_1553522023.webp)
4.6
Frame Grabber relevant Configuration
The parameters and settings, which are essential to configure the frame grabber are shown in
Table 4.5.
D-120
Pixel Clock
60 MHz
Number of Taps
2
Greyscale resolution
10 bit / 8 bit
Start Pause
6 clock cycles
Line Pause
248 ... 884 clock cycles
End Pause
242 ... 878 clock cycles
CC1
EXSYNC
CC2
not used
CC3
not used
CC4
not used
Maximal average data rate
120 MB/s (8 bit) / 240 MB/s (10 bit)
Table 4.5: Summary of parameters needed for frame grabber configuration.
CameraLink
®
port and bit assignments are compliant with the CameraLink
®
standard (see [CL]).
Table 4.6 shows the tap configurations for the D-120 camera models.
Bit
Tap 0
Tap 1
Tap 0
Tap 1
8 Bit
8 Bit
10 Bit
10 Bit
0 (LSB)
A0
B0
A0
C0
1
A1
B1
A1
C1
2
A2
B2
A2
C2
3
A3
B3
A3
C3
4
A4
B4
A4
C4
5
A5
B5
A5
C5
6
A6
B6
A6
C6
7 (MSB of 8 Bit)
A7
B7
A7
C7
8
-
-
B0
B4
9 (MSB of 10 Bit)
-
-
B1
B5
10
-
-
-
-
11 (MSB of 12 Bit)
-
-
-
-
Table 4.6: CameraLink
®
2 Tap port and bit assignments for the D-120
4.6 Frame Grabber relevant Configuration
21
Содержание CameraLink MV1-D1280
Страница 1: ...User Manual Photonfocus MV1 D1280 CameraLink Series CMOS Area Scan Camera MAN058 05 2013 V1 1...
Страница 2: ......
Страница 4: ...2...
Страница 7: ...B Revision History 81 CONTENTS 5...
Страница 8: ...CONTENTS 6...
Страница 16: ...3 How to get started CameraLink Figure 3 4 PFRemote start window 14...
Страница 24: ...4 Product Specification 22...
Страница 72: ...8 Graphical User Interface GUI 70...
Страница 74: ...9 Mechanical Considerations 72...
Страница 76: ...10 Warranty 74...
Страница 78: ...11 References 76...
Страница 82: ...A Pinouts 80...