PowerLight Models 1250DR and 2500DR

Flash Power:

Use the 

Adjust

 button to turn on the 

Flash ws

 red LED.  Adjust the PowerLight 1250DR

or 2500DR  

Flash

 power setting using the 

1/2

 or 

1/10

 f-stops UP/DOWN arrow buttons.

Ready Light:

The PowerLight 2500DR is fully charged when the READY lamp is on.  Lowest power
(32ws) charge time is a maximum of 

.8

 seconds and at full power charge (1000 ws) time

is a maximum of 

3

 seconds.  The unit may be flashed before fully charged.

The PowerLight 1250DR is fully charged when the READY lamp is on. Lowest power
(16ws) charge time is a maximum of 

.5

 seconds and at full power charge (500 ws) time is

a maximum of 

1.5

 seconds.  The unit may be flashed before fully charged.

Modeling Light:

The modeling light has three modes of operation:
1.

 

MANUAL [press the ADJUST button to turn the MODEL yellow LED on] adjusts
the modeling lamp intensity using the 

1/2

 or 

1/10

 f-stops UP/DOWN arrow buttons.

Pressing  the  MANUAL  button  a  second  time  will  change  the  mode  to  flash
adjustment and is indicated by the illuminated 

red

 LED

2.

 

TRACK mode causes the modeling lamp intensity to track the FLASH setting.  The
modeling lamp may be set to full intensity at any FLASH value, by simply pressing
the TRACK/SET button a second time, with the FLASH already set to desired watt-
seconds.  Setting is retained when user returns from another mode.

3.

 

FULL ON/OFF is exactly what it says.  Press the FULL ON/OFF button to turn the
modeling lamp OFF (LED off) or ON (LED on).

 All mode settings are retained, even after the power has been turned off.

tm

2

1

1

1

0

tm

Содержание PowerLight 1250

Страница 1: ...ator s Manual PowerLight 1250 PowerLight 1250DR PowerLight 2500DR Remote Control Accessories Unit Number Assignment Page 14 PLDIR 2 and PLDIR 1 Remote Digital Display Page 15 PLIRC 1 Infrared Remote C...

Страница 2: ...PowerLight accessories will provide you with years of dependable service With this new PL2 series optional accessories include remote power displays manual and infrared remote control and computer sof...

Страница 3: ...le 6 Do not attempt to use this appliance if it has been dropped or damaged until a qualified service person has serviced it 7 Do not operate the unit with a damaged or broken flashtube or modeling la...

Страница 4: ...f the unit control two of these tabs To mount the reflector squeeze the finger levers towards each other and tilt the reflector past the stationary top tab then past the two tabs that are controlled w...

Страница 5: ...or component failure Operation exceeding the rated cycle of the appliance may cause the fuse to open Always replace fuse with same rating of fuse An additional thermal protector is located inside the...

Страница 6: ...ust the PowerLight 1250 to its lowest flash power setting 16 watt seconds slide the FLASH control knob all the way to the left To adjust the PowerLight 1250 to its greatest flash power setting 500 wat...

Страница 7: ...e FLASH control knob in the desired position Setting is retained when user returns from another mode 3 FULL ON OFF is exactly what it says Press the FULL ON OFF button to turn the modeling lamp OFF LE...

Страница 8: ...fore fully charged Modeling Light The modeling light has three modes of operation 1 MANUAL press the ADJUST button to turn the MODEL yellow LED on adjusts the modeling lamp intensity using the 1 2 or...

Страница 9: ...contacts of X or zero delay Other units in the system are then triggered by photoslave operation It is best to connect the fill light directly to the camera since it will be positioned furthest back i...

Страница 10: ...inutes 3 minutes Continuous Sec Between Flashes 15 6 4 6 3 2 1 5 Number of Flashes Continuous 300 45 Continuous 600 90 Continuous Exposure Information The following charts give the BCPS output for var...

Страница 11: ...d Triggering Built in Photoslave Push to Test button Synchronization Jack 5 volt isolated Main Supply 105 125 VAC 60 Hz 10 amp Consumption 0 2 amps idling 15 amps charge Voltage Stabilization Plus or...

Страница 12: ...es Continuous Sec Between Flashes 15 10 6 6 3 3 3 Number of Flashes Continuous 180 30 Continuous 600 60 Continuous Exposure Information The following charts give the BCPS output for various umbrellas...

Страница 13: ...ulated Triggering Built in Photoslave Push to Test button Synchronization Jack 5 volt isolated Main Supply 105 125 VAC 60 Hz 10 Amp Consumption 0 2 amps idling 15 amps charge Voltage Stabilization Plu...

Страница 14: ...he MANUAL LED will go off Also each time the AC line power is disconnected or switched off the flashtube will flash This removes most of the flash capacitor charge to prolong the life of the unit and...

Страница 15: ...att seconds Resolution is 0 1 f stop using the 1 2 f stop and 0 1 f stop UP DOWN buttons The PLDRC 1 should be mounted to the umbrella bracket under the housing of the PowerLight on rotating mount or...

Страница 16: ...from slaving the units at a wedding or some studio units can be put in standby when not required for a shot The infrared control can easily reach to units on 12 foot stands it has been tested to 100 f...

Страница 17: ...g 100 degree coverage PL3R Shallow Background reflector rotates to control light for high key back lighting PL3RV Veil Slotted Background reflector for veil and burst lighting effects PL5R Deep Conica...

Страница 18: ...er inner panels with black blocking outer and Quick Change bracket SB22 22 x22 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket SB36 36 x36 Satin white fr...

Страница 19: ...power to the unit After a 3 minute cool off period the power will return This is a unit protecting feature and can be caused by user actions or circuit failure Modeling light does not turn on Probabl...

Страница 20: ...shipping product abuse or use other than the intended photographic applications Any product modifications will render this warranty void Use of other manufacturer s accessories which restrict normal...

Отзывы: