Unpacking and Setup: (continued)

The unit is shipped with the modeling lamp and flashtube not installed.  While installing
the modeling lamp and flashtube (with glove or clean cloth to protect the hand) be sure
they  are  properly  inserted  and  tight  to  avoid  arcing  and  failure  of  the  socket  contacts
during operation. Do not touch the glass tubes with bare hands, as normal body oils will
shorten the bulb’s life.   Always use a clean cloth or wear gloves to protect your hand
from glass breakage and heat.

The 7 1/2 inch reflector is attached by the “quick-change” mechanism.  Three tabs on the
unit grip the ring on the reflector.  Finger levers located on the top of the unit control two
of these tabs.   To mount the reflector, squeeze the finger levers towards each other and
tilt the reflector past the stationary top-tab, then past the two tabs that are controlled with
the  levers.   Release  the  finger  levers  and  make  sure  all  three  tabs  are  securing  the
reflector (see illustration below.)  All PowerLight accessory reflectors and soft boxes are
designed for use with this “quick-change” system or onto this 7 _ inch reflector.

                               Squeeze levers to mount
                               reflector in locked position.

                            Punch out hole for                              Professional plug-in
                            umbrella rod.                                      flashtube.

With  power  switch  OFF,  attach  the  line  cord  to  the  power-input  connector,
located  on  the  bottom  of  the  PowerLight,  and  connect  it  to  a  grounded  wall
outlet.   Turn the power switch ON. The READY light will light when the unit
has  charged  to  the  power  level  set  by  the  FLASH  power  control.

Содержание PowerLight 1250

Страница 1: ...ator s Manual PowerLight 1250 PowerLight 1250DR PowerLight 2500DR Remote Control Accessories Unit Number Assignment Page 14 PLDIR 2 and PLDIR 1 Remote Digital Display Page 15 PLIRC 1 Infrared Remote C...

Страница 2: ...PowerLight accessories will provide you with years of dependable service With this new PL2 series optional accessories include remote power displays manual and infrared remote control and computer sof...

Страница 3: ...le 6 Do not attempt to use this appliance if it has been dropped or damaged until a qualified service person has serviced it 7 Do not operate the unit with a damaged or broken flashtube or modeling la...

Страница 4: ...f the unit control two of these tabs To mount the reflector squeeze the finger levers towards each other and tilt the reflector past the stationary top tab then past the two tabs that are controlled w...

Страница 5: ...or component failure Operation exceeding the rated cycle of the appliance may cause the fuse to open Always replace fuse with same rating of fuse An additional thermal protector is located inside the...

Страница 6: ...ust the PowerLight 1250 to its lowest flash power setting 16 watt seconds slide the FLASH control knob all the way to the left To adjust the PowerLight 1250 to its greatest flash power setting 500 wat...

Страница 7: ...e FLASH control knob in the desired position Setting is retained when user returns from another mode 3 FULL ON OFF is exactly what it says Press the FULL ON OFF button to turn the modeling lamp OFF LE...

Страница 8: ...fore fully charged Modeling Light The modeling light has three modes of operation 1 MANUAL press the ADJUST button to turn the MODEL yellow LED on adjusts the modeling lamp intensity using the 1 2 or...

Страница 9: ...contacts of X or zero delay Other units in the system are then triggered by photoslave operation It is best to connect the fill light directly to the camera since it will be positioned furthest back i...

Страница 10: ...inutes 3 minutes Continuous Sec Between Flashes 15 6 4 6 3 2 1 5 Number of Flashes Continuous 300 45 Continuous 600 90 Continuous Exposure Information The following charts give the BCPS output for var...

Страница 11: ...d Triggering Built in Photoslave Push to Test button Synchronization Jack 5 volt isolated Main Supply 105 125 VAC 60 Hz 10 amp Consumption 0 2 amps idling 15 amps charge Voltage Stabilization Plus or...

Страница 12: ...es Continuous Sec Between Flashes 15 10 6 6 3 3 3 Number of Flashes Continuous 180 30 Continuous 600 60 Continuous Exposure Information The following charts give the BCPS output for various umbrellas...

Страница 13: ...ulated Triggering Built in Photoslave Push to Test button Synchronization Jack 5 volt isolated Main Supply 105 125 VAC 60 Hz 10 Amp Consumption 0 2 amps idling 15 amps charge Voltage Stabilization Plu...

Страница 14: ...he MANUAL LED will go off Also each time the AC line power is disconnected or switched off the flashtube will flash This removes most of the flash capacitor charge to prolong the life of the unit and...

Страница 15: ...att seconds Resolution is 0 1 f stop using the 1 2 f stop and 0 1 f stop UP DOWN buttons The PLDRC 1 should be mounted to the umbrella bracket under the housing of the PowerLight on rotating mount or...

Страница 16: ...from slaving the units at a wedding or some studio units can be put in standby when not required for a shot The infrared control can easily reach to units on 12 foot stands it has been tested to 100 f...

Страница 17: ...g 100 degree coverage PL3R Shallow Background reflector rotates to control light for high key back lighting PL3RV Veil Slotted Background reflector for veil and burst lighting effects PL5R Deep Conica...

Страница 18: ...er inner panels with black blocking outer and Quick Change bracket SB22 22 x22 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket SB36 36 x36 Satin white fr...

Страница 19: ...power to the unit After a 3 minute cool off period the power will return This is a unit protecting feature and can be caused by user actions or circuit failure Modeling light does not turn on Probabl...

Страница 20: ...shipping product abuse or use other than the intended photographic applications Any product modifications will render this warranty void Use of other manufacturer s accessories which restrict normal...