background image

15

Advanced PL2 series Accessories.

PLDD-1 Digital display for Model 1250 only.

The PLDD-1 is a digital display to enhance the resolution and repeatability of the Model
1250’s 

Flash

 analog slide-pot control.  It displays only 

Flash

 power, over the full range

of 16 to 500 watt-seconds.  Resolution of the PLDD-1 is 0.1 f-stop.

The PLDD-1 should be mounted to the umbrella bracket under the housing of the Model
1250  PowerLight,  on  flexible  rotating  mount,  or  on  an  extension  cable,  for  better
viewing.

PLDRC-1  Remote  digital  display  and  flash  adjustment  for  models
1250DR and 2500DR.

The PLDRC-1 is a digital display to enhance the visibility of, and to change the 

Flash

power setting.   It displays and controls only 

Flash

 power, over the full range of watt-

seconds.  Resolution is 0.1 f-stop, using the 1/2 f-stop and 0.1 f-stop UP/DOWN buttons.

The  PLDRC-1  should  be  mounted  to  the  umbrella  bracket  under  the  housing  of  the
PowerLight, on rotating mount, or on an extension cable, for better viewing and easier
control accessibility.

PLDIR-2  Remote  digital  display  and  Infrared  receiver  for  models
1250DR and 2500DR. 

(must be used with PLIRC-1 controller)

The  PLDIR-2  is  a  digital  display  to  enhance  the  visibility  of,  and  to  receive  infrared
signals to control all functions of the 1250DR and 2500DR PowerLights.  It displays both
Flash  power  and  Modeling  lamp  power  and  unit  number.   It  has  a  green  READY
indicator  and  a  BI-color  indicator  for  Flash  or  Model.   Behind  a  small  window  is  an
infrared receiver.  Resolution is 0.1 f-stop.

The PLDIR-2 should be mounted to the umbrella bracket under the housing of
the PowerLight, on rotating mount, or on an extension cable, for better viewing
and infrared control.

Содержание PowerLight 1250

Страница 1: ...ator s Manual PowerLight 1250 PowerLight 1250DR PowerLight 2500DR Remote Control Accessories Unit Number Assignment Page 14 PLDIR 2 and PLDIR 1 Remote Digital Display Page 15 PLIRC 1 Infrared Remote C...

Страница 2: ...PowerLight accessories will provide you with years of dependable service With this new PL2 series optional accessories include remote power displays manual and infrared remote control and computer sof...

Страница 3: ...le 6 Do not attempt to use this appliance if it has been dropped or damaged until a qualified service person has serviced it 7 Do not operate the unit with a damaged or broken flashtube or modeling la...

Страница 4: ...f the unit control two of these tabs To mount the reflector squeeze the finger levers towards each other and tilt the reflector past the stationary top tab then past the two tabs that are controlled w...

Страница 5: ...or component failure Operation exceeding the rated cycle of the appliance may cause the fuse to open Always replace fuse with same rating of fuse An additional thermal protector is located inside the...

Страница 6: ...ust the PowerLight 1250 to its lowest flash power setting 16 watt seconds slide the FLASH control knob all the way to the left To adjust the PowerLight 1250 to its greatest flash power setting 500 wat...

Страница 7: ...e FLASH control knob in the desired position Setting is retained when user returns from another mode 3 FULL ON OFF is exactly what it says Press the FULL ON OFF button to turn the modeling lamp OFF LE...

Страница 8: ...fore fully charged Modeling Light The modeling light has three modes of operation 1 MANUAL press the ADJUST button to turn the MODEL yellow LED on adjusts the modeling lamp intensity using the 1 2 or...

Страница 9: ...contacts of X or zero delay Other units in the system are then triggered by photoslave operation It is best to connect the fill light directly to the camera since it will be positioned furthest back i...

Страница 10: ...inutes 3 minutes Continuous Sec Between Flashes 15 6 4 6 3 2 1 5 Number of Flashes Continuous 300 45 Continuous 600 90 Continuous Exposure Information The following charts give the BCPS output for var...

Страница 11: ...d Triggering Built in Photoslave Push to Test button Synchronization Jack 5 volt isolated Main Supply 105 125 VAC 60 Hz 10 amp Consumption 0 2 amps idling 15 amps charge Voltage Stabilization Plus or...

Страница 12: ...es Continuous Sec Between Flashes 15 10 6 6 3 3 3 Number of Flashes Continuous 180 30 Continuous 600 60 Continuous Exposure Information The following charts give the BCPS output for various umbrellas...

Страница 13: ...ulated Triggering Built in Photoslave Push to Test button Synchronization Jack 5 volt isolated Main Supply 105 125 VAC 60 Hz 10 Amp Consumption 0 2 amps idling 15 amps charge Voltage Stabilization Plu...

Страница 14: ...he MANUAL LED will go off Also each time the AC line power is disconnected or switched off the flashtube will flash This removes most of the flash capacitor charge to prolong the life of the unit and...

Страница 15: ...att seconds Resolution is 0 1 f stop using the 1 2 f stop and 0 1 f stop UP DOWN buttons The PLDRC 1 should be mounted to the umbrella bracket under the housing of the PowerLight on rotating mount or...

Страница 16: ...from slaving the units at a wedding or some studio units can be put in standby when not required for a shot The infrared control can easily reach to units on 12 foot stands it has been tested to 100 f...

Страница 17: ...g 100 degree coverage PL3R Shallow Background reflector rotates to control light for high key back lighting PL3RV Veil Slotted Background reflector for veil and burst lighting effects PL5R Deep Conica...

Страница 18: ...er inner panels with black blocking outer and Quick Change bracket SB22 22 x22 Satin white front panel silver inner panels with black blocking outer and Quick Change bracket SB36 36 x36 Satin white fr...

Страница 19: ...power to the unit After a 3 minute cool off period the power will return This is a unit protecting feature and can be caused by user actions or circuit failure Modeling light does not turn on Probabl...

Страница 20: ...shipping product abuse or use other than the intended photographic applications Any product modifications will render this warranty void Use of other manufacturer s accessories which restrict normal...

Отзывы: