P1 ENGRAVING UNIT
103072_00_en
PHOENIX CONTACT
11
•
Now unscrew the depth adjuster from the engraving
spindle.
Figure 18
Loosening the engraving spindle
•
Press the rotary knob at the end of the engraving
spindle and turn counter clockwise.
The collet chuck is now open and the graver can be
carefully removed.
Figure 19
Securing the graver in the adjustment aid
•
Insert the new graver in the adjustment aid with the tip
pointing towards the front and secure it using the
knurled screw.
•
Push the graver with the adjustment aid into the collet
chuck and screw it back together by pressing the rotary
knob at the end of the engraving spindle and turning
clockwise.
•
Screw the depth adjuster back onto the engraving
spindle.
The depth adjuster is in the zero position when a gap of
three millimeters is achieved between the depth adjuster
and engraving spindle.
Figure 20
Adjustment aid as a spacer
•
Use the open end of the adjustment aid as a spacer
between the depth adjuster and engraving spindle.
•
Now insert the engraving spindle back into the
engraving head and line up the markings on the depth
adjuster and engraving head.
•
Retighten the termination block.
Cleaning and Maintaining the Engraving
Unit
Changing the Vacuum Cleaner Bag
Figure 21
Opening the vacuum cleaner cover
Replacement vacuum cleaner bags can be ordered from
Phoenix Contact (P1 ENGRAVING VC BAG, Order No.
5145559).
•
Push down the latch above the suction tube on the
vacuum cleaner. The cover opens with the suction tube
and vacuum cleaner bag.
•
Remove the suction tube by simultaneously turning
and pulling it.
For assembly, perform the above in reverse order.
Only loosen the collet chuck so that the graver
can be removed.
Only use Phoenix Contact gravers. If gravers
from other manufacturers are used, we accept
no guarantee as to the lettering quality and for
damage to units.
To ensure the correct length of the graver,
always use the adjustment aid supplied.
Before starting any maintenance work
disconnect the engraving unit from the mains.
Protect the engraving unit against dust and
other contamination. Cover the device when it
is not being used.
Never oil the mechanical parts of the engraving
unit.