onlinecomponents.com
P1 ENGRAVING UNIT
8
PHOENIX CONTACT
103072_00_en
•
Make sure that the plotter and control unit are switched
off.
•
Manually position the engraving head in the bottom
right corner of the CMS-P1-PLOTTERs.
•
Now attach the suction tube to the engraving head,
bend the tube slightly, and secure it in the clamp on the
support pipe.
•
Then insert the end of the tube in the opening on the
vacuum cleaner.
•
Now attach the engraving cable to the engraving head,
bend the 3-pos. cable slightly, and secure it in the
clamp on the support pipe.
•
Connect the other end of the cable to the control unit
and tighten the screw connections of the connector.
Fitting the Cover
The blue-green cover can only be fitted on the engraving
head in one direction (long side towards the right on the
front).
•
Fit the cover in the correct position on the engraving
head.
Switching From Plotting to Engraving (Test Run)
•
Always switch the control unit on first
via the mains
switch on the back of the device.
•
Then
switch the CMS-P1-PLOTTER on.
The engraving unit moves towards the zero position.
This is accompanied by a brief "humming" noise. The
plotter then moves to the zero position.
•
Switch the plotter and control unit off again.
Inserting Engraving Material
•
Make sure that the plotter and control unit are switched
off.
•
Place the CMS-P1-M/GPE ENGRAVING plastic
magazine with the non-slip pad and engraving material
on the plotter in the corresponding holders.
•
Manually move the engraving head over the engraving
material to check the gap between the engraving
spindle and the engraving material.
Figure 10
Gap
•
The control unit can now be switched on followed by
the plotter; the engraving unit is ready to start.
Engraving
Important Notes on Engraving
Risk of damage to the device
Always switch the control unit on before the
plotter.
There must be
no
magazine
on the plotter.
Secure the engraving material to be
processed.
Make sure that the carrier plate has sufficient
adhesive strength and clean regularly under
running water.
Only use non-slip pads from Phoenix Contact
to hold the materials to be processed.
There must be around 2 mm of space between
the bottom end of the engraving spindle and
the engraving material.
If the gap is greater or smaller than 2 mm, use
the calibration block to check the right-angle
alignment of the engraving unit.
The engraving unit is designed for use on the
CMS-P1-PLOTTER for the purpose of
engraving plastic labels. The use of other
materials, such as aluminum, brass, steel, and
glass is not permitted.
The use of lubricants and coolants is not
permitted, as the vacuum cleaner used cannot
handle liquid materials.
Only use Phoenix Contact gravers.
Only use the engraving unit in dust-free rooms.
An excessively high level of dust can result in
the sensitive bearing of the engraving spindle
becoming clogged with dust and quickly
wearing out.
2 mm