DC20 Lifting Column
Installation
92299 1.0
21
Installation: Head and foot of the DC20 lifting column
Use M8x40 threaded cap screws (strength class 8.8) (as shown in Figure 8) for mounting the
DC20 lifting column. The tightening torque should be between 15 and 17 Nm.
The screws must not be loosened and re-tightened more than 2 times (only in the same thread!)
to prevent damage and weakening of the screw connection.
Figure 8
Mounting holes for the installation: Head and foot of DC20 lifting column (in mm)
A
Head
B
Foot
116
77
154
113
A
B