Phoenix Contact FL NAT SMN 8TX Скачать руководство пользователя страница 4

Please observe the following notes

PHOENIX CONTACT

General terms and conditions of use for technical documentation

Phoenix Contact reserves the right to alter, correct, and/or improve the technical documen-

tation and the products described in the technical documentation at its own discretion and 

without giving prior notice, insofar as this is reasonable for the user. The same applies to any 

technical changes that serve the purpose of technical progress.

The receipt of technical documentation (in particular user documentation) does not consti-

tute any further duty on the part of Phoenix Contact to furnish information on modifications 

to products and/or technical documentation. You are responsible to verify the suitability and 

intended use of the products in your specific application, in particular with regard to observ-

ing the applicable standards and regulations. All information made available in the technical 

data is supplied without any accompanying guarantee, whether expressly mentioned, im-

plied or tacitly assumed. 

In general, the provisions of the current standard Terms and Conditions of Phoenix Contact 

apply exclusively, in particular as concerns any warranty liability.

This manual, including all illustrations contained herein, is copyright protected. Any 

changes to the contents or the publication of extracts of this document is prohibited.

Phoenix Contact reserves the right to register its own intellectual property rights for the 

product identifications of Phoenix Contact products that are used here. Registration of such 

intellectual property rights by third parties is prohibited.

Other product identifications may be afforded legal protection, even where they may not be 

indicated as such.

Содержание FL NAT SMN 8TX

Страница 1: ...User manual User manual for the NAT router with integrated switch UM EN FL NAT SMN 8TX...

Страница 2: ...en_04 User manual for the NAT router with integrated switch UM EN FL NAT SMN 8TX 04 Designation Version Order No FL NAT SMN 8TX 2989365 FL NAT SMN 8TX M 2702443 User manual Designation Revision Order...

Страница 3: ...www phoenixcontact com Published by PHOENIX CONTACT GmbH Co KG Flachsmarktstra e 8 32825 Blomberg GERMANY Should you have any suggestions or recommendations for improvement of the contents and layout...

Страница 4: ...ducts in your specific application in particular with regard to observ ing the applicable standards and regulations All information made available in the technical data is supplied without any accompa...

Страница 5: ...signing IP parameters at the WAN interface port 1 3 1 3 1 2 Assigning IP parameters at the LAN interface port 2 to port 8 3 2 3 1 3 IP address assignment using IPAssign exe 3 2 3 2 Frame switching at...

Страница 6: ...s involved 5 1 5 1 2 Connection failure Example 5 11 5 1 3 Mixed operation of RSTP and STP 5 12 5 1 4 Topology detection of a Rapid Spanning Tree network RSTP 5 12 5 1 5 Configuration notes for Rapid...

Страница 7: ...ort 8 in the lower level machine network In addition to the switch and routing function further IT functions are available such as redundancy port mirroring or LLDP The FL NAT SMN 8TX M can be configu...

Страница 8: ...ing Support of various topologies and meshed structures as well as ring topologies with special ring detection Configuration of the switch using web based management SNMP or locally via an RS 232 inte...

Страница 9: ...of DIN rail including MEM PLUG 175 mm 1 2 Status and diagnostic indicators Des Color Status Meaning US1 Green ON Supply voltage 1 in the tolerance range OFF Supply voltage 1 too low US2 Green ON Supp...

Страница 10: ...MODE LED at the port Status Meaning An additional LED is located on the front of the FL NAT SMN 8TX M for each port The function of the second LED MOD for each port can be set using the MODE switch se...

Страница 11: ...be mounted to the right and left of the device to stop the modules from slipping on the DIN rail Mounting 1 Place the module onto the DIN rail from above A The upper holding keyway of the module must...

Страница 12: ...e positive latch using a suitable tool e g screwdriver The positive latch remains snapped out Then swivel the bottom of the module away from the DIN rail slightly A Next lift the module upwards away f...

Страница 13: ...ltage source Redundant 24 V DC supply Figure 2 4 Supplying the FL NAT SMN 8TX M using two voltage sources If redundant power supply monitoring is active default setting an error is indicated if only o...

Страница 14: ...age 4 26 2 2 3 Assignment of the RJ45 Ethernet connectors In the event of non redundant power supply the device indicates a supply voltage failure by opening the alarm contact This error message can b...

Страница 15: ...ing All Factoryline devices must be grounded so that any possible interference is shielded from the data telegram and discharged to ground potential A conductor of at least 2 5 mm2 must be used for gr...

Страница 16: ...FL NAT SMN 8TX M 2 6 PHOENIX CONTACT 7966_en_04...

Страница 17: ...ng tool which is available free of charge can be used to assign the IP parameters see IP address assignment using IPAssign exe on page 3 2 The IP parameters of the WAN port can be configured staticall...

Страница 18: ...nk www phoenixcontact net catalog Enter the order number 2832700 in the search field for example The IP addressing tool can be found under Configuration file Double click on the IPAssign exe file In t...

Страница 19: ...ens IP address of the PC MAC address of the selected device IP parameters of the selected device IP address subnet mask and gateway address Any incorrect settings Figure 3 3 Set IP Address window with...

Страница 20: ...inish 3 2 Frame switching at ports 2 8 Devices in the company network WAN can access IP addresses of machines at ports 2 8 in the production cell LAN without additional configuration The FL NAT SMN 8T...

Страница 21: ...exceeded a specific age default 40 seconds adjustable from 10 to 825 seconds aging time 3 2 4 Prioritization The switch supports four priority queues traffic classes according to IEEE 802 1D for adjus...

Страница 22: ...features The preferred interfaces are the web interface and SNMP interface Das WEB Interface erreicht man durch Eingabe der WAN oder LAN IP Adresse in einem Browser z B Internet Explorer Mozilla Fire...

Страница 23: ...press and hold down the mode button for at least five seconds When Smart mode is active the three LEDs flash When Smart Mode is started the switch is initially in the Exit without changes state 3 5 1...

Страница 24: ...FL NAT SMN 8TX M 3 8 PHOENIX CONTACT 7966_en_04...

Страница 25: ...Hyper Text Transfer Protocol a standard browser can be used Access is via the URL http IP address of the device Example http 172 16 29 112 For full operation of the web pages the browser must support...

Страница 26: ...for the first ten users logged in simultaneously All other users must confirm each configuration modification by entering the password until less than ten users are logged in 4 1 3 Functions informat...

Страница 27: ...to the device web server and the start page is displayed Figure 4 1 Start page for web based management 4 1 3 2 General Instructions Contains a brief description of WBM information and a navigation t...

Страница 28: ...ONTACT 7966_en_04 4 1 3 3 Device Information General menu This page contains a range of static information about the device and the manufacturer as well as some user specific settings Figure 4 3 Devic...

Страница 29: ...Configuration and diagnostics 7966_en_04 PHOENIX CONTACT 4 5 Technical Data menu This page lists the main technical data Figure 4 4 Technical Data web page...

Страница 30: ...FL NAT SMN 8TX M 4 6 PHOENIX CONTACT 7966_en_04 Hardware Installation menu Here you will find a diagram that lists all the elements of the device Figure 4 5 Hardware Installation web page...

Страница 31: ...Local Diagnostics menu This page describes the meaning of the switchable diagnostic and status indicators Figure 4 6 Local Diagnostics web page Serial Port menu This page lists the transmission parame...

Страница 32: ...l Configuration This page displays the set IP parameters and addressing mechanism This page displays the parameters of both the WAN port and the LAN port To change the IP parameters via WBM Static ass...

Страница 33: ...en_04 PHOENIX CONTACT 4 9 System Identification menu This menu is used to display or modify user specific device data e g location device name or function This device data is also available in SNMP Fi...

Страница 34: ...part of the table is used to view or modify the IP addresses of the two trap receivers Trap Configuration Sending of traps can be individually enabled disabled here SNMP Trap Connection Test Once the...

Страница 35: ...arried out automatically following a firmware update The desired option can be selected in WBM For firmware updates a TFTP server is required Following a firmware update it is recommended that you che...

Страница 36: ...for the automatic updating of the web pages Here you can also set the refresh interval for automatic update of different web pages If the interval is set to 0 the pages will no longer be updated By de...

Страница 37: ...eral menu This table is used to view all parameters that are required to save the active configuration or load a new configuration and to modify them by entering a valid password It can also be used t...

Страница 38: ...states for Status of current configuration The configuration has been modified but not saved also indicated by the flashing floppy disk icon Saving the current configuration The current configuration...

Страница 39: ...elivery web page Load the last stored con figuration The last configuration stored on the device can be reactivated All modifications made to the configuration since it was last saved are lost Figure...

Страница 40: ...eb page When a configuration is uploaded from the FL NAT SMN 8TX M to a PC device to host the last saved version is transmitted If you want to transmit the active configuration first save it again Sav...

Страница 41: ...ces To duplicate devices using a configuration file observe the following Create a point to point connection between an FL NAT SMN 8TX M and the management station Load the configuration file on the F...

Страница 42: ...FL NAT SMN 8TX M memory The result is displayed in text format Figure 4 20 Configuration comparison web page Clear Memory Plug Here you can delete the memory plug by entering a valid password Figure...

Страница 43: ...lid password Save the configuration beforehand so that configuration modifications are retained or can be activated via a restart Device mode The following modes are available Static Route Standard ro...

Страница 44: ...ant port number opens a port specific page Port Configuration Figure 4 23 Port Table web page Ports Port Cfg Table menu This menu provides an overview of the important configuration settings for all p...

Страница 45: ...t Configuration Table web page When setting the transmission mode make sure that the same settings have been made at both ends of the connection If the settings are not the same this can result in inc...

Страница 46: ...FL NAT SMN 8TX M 4 22 PHOENIX CONTACT 7966_en_04 Ports Port Configuration menu Offers individual configuration options for each port Figure 4 25 Port Configuration web page...

Страница 47: ...X CONTACT 4 23 Ports Port Statistics menu This menu provides detailed statistical information about the volume of data for each individual port On this page counter states can also be set to zero for...

Страница 48: ...the destination port which records the data yet must not itself be activated Figure 4 27 Port Mirroring web page WBM prevents the same ports from being set i e the source port and destination port mu...

Страница 49: ...on and diagnostics 7966_en_04 PHOENIX CONTACT 4 25 Diagnostics Display menu The Display web page contains status information about the firmware the alarm contact and the power supply Figure 4 28 Displ...

Страница 50: ...FL NAT SMN 8TX M 4 26 PHOENIX CONTACT 7966_en_04 Diagnostics Alarm Contact Menu Here you can set whether and for which events the alarm contact can be used Figure 4 29 Alarm Contact web page...

Страница 51: ...e Restarting the device deletes all entries Figure 4 30 Event Table web page The Clear button can be used to delete entries in the event table The following events are listed in the event table Event...

Страница 52: ...disabled RSTP topology changed RSTP elected this switch as new root Power Supply US1 lost Power Supply US2 lost Power Supply US1 and US2 are connected now LLDP Agent enabled LLDP Agent disabled LLDP...

Страница 53: ...4 31 MAC Address Table web page The Clear button can be used to delete entries in the MAC address table 4 1 3 6 LLDP General For information about LLDP please refer to Section LLDP Link Layer Discove...

Страница 54: ...he desired router mode on the Services web page see also Section Services menu on page 4 19 Then set the desired router configuration The IP address area of this device to which the router should be a...

Страница 55: ...on page 4 19 Then set the desired router configuration 1 1 NAT menu The settings for 1 1 NAT can be made here In 1 1 NAT mode the IP address area is mirrored in other areas Figure 4 33 1 1 NAT menu T...

Страница 56: ...at all IP addresses can be accessed from the virtual network 4 2 3 1 Configuration of virtual NAT routing Select the desired router mode on the Services web page see also Section Services menu on page...

Страница 57: ...connection can be established between the devices in the LAN and WAN the LAN IP address of the FL NAT SMN 8TX M must be set as the gateway address on the devices in the LAN network For the devices in...

Страница 58: ...dwidth limit is reached further broadcast or multicast packets are rejected The set bandwidth applies for the incoming data traffic of each individual port The following configuration options are prov...

Страница 59: ...ata from the manager to the MIB In the event of an emergency the agents can also send messages traps directly to the manager 4 3 2 Schematic view of SNMP management Figure 4 36 Schematic view of SNMP...

Страница 60: ...parameters under any circumstances Phoenix Contact provides notification of ASN1 SNMP objects by publishing their descriptions on the Internet Reading SNMP objects is not password protected However a...

Страница 61: ...IB mi2 flWorkBasicHWRevision Status information for supply voltages FL NAT Router V320 MIB mi2 flWorkBasicPowerStat MAC address of the switch FL NAT Router V320 MIB mi2 flWorkNetIfParamPhyAddress Firm...

Страница 62: ...kFWInfoEventTable Device web browser activation deactivation FL NAT Router V320 MIB mi2 flWorkFWCtrlHTTP Web browser refresh interval of the web pages FL NAT Router V320 MIB mi2 flWorkFWCtrlWebPageRef...

Страница 63: ...onding emulation between the switch and a PC e g HyperTerminal under Windows and enables access to the user interface 4 4 1 1 Interface configuration Make the following settings on your Windows PC Fig...

Страница 64: ...tic BootP Resetting to the default settings Activating deactivating the web server and SNMP Activating deactivating the RSTP redundancy mechanism Reset 4 4 2 2 Structure of the user interface screens...

Страница 65: ...ia RS 232 In order for the switch to perform its function it requires an IP address which can be assigned via the serial interface If the switch already has an IP address it uses this existing IP addr...

Страница 66: ...FL NAT SMN 8TX M 4 42 PHOENIX CONTACT 7966_en_04...

Страница 67: ...be operated as active R STP components in the network 2 Connect the switches to form a meshed topology 5 1 1 Enabling R STP on all switches involved R STP can be activated via web based management vi...

Страница 68: ...ufficient to set the Rapid Spanning Tree Status to Enable in order to start R STP using default settings Priority values can be specified for the switch The bridge and backup root can be specified via...

Страница 69: ...switches along the relevant path if RSTP is used The Large Tree Support option could provide an RSTP ring topology with up to 57 devices When using large tree support please note the following In the...

Страница 70: ...ame meaning as for STP These values are used when this switch becomes a root The values currently used can be found under R STP General Hello Time Specifies the time interval within which the root bri...

Страница 71: ...mination device ports become edge ports i e ports that go to the Forwarding state immediately after restart Protocol Indicates the redundancy protocol used R STP State Indicates the current R STP stat...

Страница 72: ...sion of the active topology however MAC addresses are learned Blocking Discarding The port has a link but has not been set to the Discarding state by RSTP R STP Port Configuration Table Figure 5 4 R S...

Страница 73: ...fier A switch ID consists of eight bytes as an unsigned integer value When comparing two switch IDs the one with the lowest numeric value is of higher i e better priority The first two bytes contain t...

Страница 74: ...value When comparing two port IDs the one with the lowest numeric value is of higher i e better priority Figure 5 5 R STP Port Configuration web page Port Number Indicates the number of the port curre...

Страница 75: ...from the Discarding state to the Forwarding state Additional parameters provide information about the network paths in a stable topology that are used by the BPDU telegrams Designated Root Root bridge...

Страница 76: ...the actual topology Figure 5 7 RSTP ring table Information in WBM The following information is displayed on the web page and via SNMP Local ring ports These two ports of this switch belong to the rin...

Страница 77: ...2 1D MAC Address 1 3 5 7 2 4 6 8 9 11 13 15 10 12 14 16 9 16 10 11 12 13 14 15 1 8 2 3 4 5 6 7 MODE ACT 100 FD US1 US2 FAIL X19 V 24 X17 US1 GND US2 GND X18 R1 R2 LNK MODE 1 2 X1 LNK MODE 1 2 X2 LNK M...

Страница 78: ...il the decisions described above have been made Therefore loops which could otherwise occur during the network startup phase because no data path is interrupted are prevented 5 1 4 1 Topology modifica...

Страница 79: ...Spanning Tree protocol is deactivated at a port the corresponding port is in fast forwarding mode A fast forwarding port Ignores all BPDUs that are received at this port Does not send any BPDUs Switch...

Страница 80: ...order of frames may be changed 5 1 4 4 Enabling via serial interface Establish a connection to the switch The procedure is described in Section Management via local RS 232 communication interface on...

Страница 81: ...ore a data path can also consist of a connection of a Spanning Tree switch to A termination device A network segment in which no loops may occur which consists of several infrastructure components hub...

Страница 82: ...ath FL SWITCH MCS 16TX Ord No 28 32 70 0 00 A0 45 1B D2 1D MAC Address 1 3 5 7 2 4 6 8 9 11 13 15 10 12 14 16 9 16 10 11 12 13 14 15 1 8 2 3 4 5 6 7 MODE ACT 100 FD US1 US2 FAIL X19 V 24 X17 US1 GND U...

Страница 83: ...WITCH MM HS Ord No 28 32 32 6 US2 US1 GND GND R1 R2 00A0451BDD MAC Address V 24 FL SWITCH MCS 16TX Ord No 28 32 70 0 00 A0 45 1B D2 1D MAC Address 1 3 5 7 2 4 6 8 9 11 13 15 10 12 14 16 9 16 10 11 12...

Страница 84: ...100 FD US1 US2 FAIL X19 V 24 X17 US1 GND US2 GND X18 R1 R2 FL SWITCH MCS 16TX Ord No 28 32 70 0 00 A0 45 1B D2 1D MAC Address 1 3 5 7 2 4 6 8 9 11 13 15 10 12 14 16 9 16 10 11 12 13 14 15 1 8 2 3 4 5...

Страница 85: ...ort The port of a switch with the lowest root path costs is always the active port If the same root path costs have been calculated for two or more ports the switch priority followed by the port prior...

Страница 86: ...are preset to a value of 19 default setting recommended for 100 Mbps and can be modified at any time by the user Selecting a designated port At every designated switch the port with the most cost effe...

Страница 87: ...ree Specifying the root switch The root switch is assigned via the assignment of an appropriate priority for the Spanning Tree segment Set the highest priority lowest value in the Priority field on th...

Страница 88: ...e protocol using the fast forwarding function One of the following requirements must be met so that the Spanning Tree protocol can be disabled for a port A termination device is connected to the port...

Страница 89: ...ime for a ring topology corresponds to the maximum number of components with active Spanning Tree Figure 5 15 Example 1 for the relevant path Modifying the protocol timers may result in unstable netwo...

Страница 90: ...1 US2 Fail Reset MODE ACT 100 FD FL SWITCH MM HS Ord No 28 32 32 6 US2 US1 GND GND R1 R2 00A0451BDD MAC Address V 24 LNK MODE 1 2 X1 LNK MODE 1 2 X2 LNK MODE 1 2 X3 LNK MODE 1 2 X4 US1 US2 Fail Reset...

Страница 91: ...rk The MRP manager constantly sends test telegrams known as watchdogs via the logically closed port In the event of an error in the network this is detected by the MRP manager and the watchdog path is...

Страница 92: ...GND GND R1 R2 00A0451BDD MAC Address V 24 00 A0 45 06 04 02 MAC Address 1 2 3 4 LINK Mode US2 FAIL X9 US1 GND US2 GND X10 R1 R2 FL SWITCH SMSC 8GT Ord No 2891123 US1 X11 MEM MODE SPD FD ACT 5 6 7 8 X...

Страница 93: ...6 7 8 X12 V 24 1 3 5 7 2 4 6 8 00 A0 45 06 04 02 MAC Address 1 2 3 4 LINK Mode US2 FAIL X9 US1 GND US2 GND X10 R1 R2 FL SWITCH SMSC 8GT Ord No 2891123 US1 X11 MEM MODE SPD FD ACT 5 6 7 8 X12 V 24 1 3...

Страница 94: ...me of last topology modification Ring port numbers and status of the ports Forwarding or Blocking Figure 6 4 MRP General web page for an MRP client 6 3 2 MRP Configuration The MRP Configuration web pa...

Страница 95: ...Protocol LLDP according to 802 1ab is used by network devices to learn and maintain the individual neighbor relationships Function A network infrastructure component transmits a port specific BPDU Br...

Страница 96: ...set Transmit LLDP BPDUs with a TTL value of 0 seconds to all ports Delete sender from the list of neighbors Link up Send port specific LLDP BPDUs Include sender in the list of neighbors Link down Dele...

Страница 97: ...very Protocol Figure 7 1 Link Layer Discovery Protocol web page The Message Time To Live is determined by multiplying the Message Transmit Interval with the Message Transmit Hold Multiplier The Messag...

Страница 98: ...web page Type An icon is displayed here which corresponds to the neighboring device type Ethernet Device is displayed in general for devices produced by other manufacturers Address Indicates the mana...

Страница 99: ...gree of protection IP20 IEC 60529 Protection class Class 3 VDE 0106 IEC 60536 Humidity Operation 5 95 non condensing Storage 5 95 non condensing Air pressure Operation 86 kPa to 108 kPa 1500 m above s...

Страница 100: ...etwork segment length 100 m Mechanical tests Shock test according to IEC 60068 2 27 Operation 25 g Half sine shock pulse Storage transport 50 g Half sine shock pulse Vibration resistance according to...

Страница 101: ...connections FL PF 2TX CAT 6 2891068 1 Angled patch connector with eight RJ45 CAT6 network connections FL PF 8TX CAT 6 2891071 1 Patch cable CAT6 pre assembled 0 3 m long FL CAT6 PATCH 0 3 2891181 10...

Страница 102: ...AT5 6 PATCH yellow FL PATCH CCODE YE 2891592 20 Lockable security element for FL CAT5 6 PATCH FL PATCH GUARD 2891424 20 Color marker for FL PATCH GUARD black FL PATCH GUARD CCODE BK 2891136 12 Color m...