MACX MCR-VAC
2906239
MACX MCR-VAC-PT
2906244
9
1
2
4
3
6
7
8
5
-
+ EN
+
EN+
EN-
4.1
5.1
4.2
5.2
4.3
5.3
3.
1
1.1
1.2
1.3
1.4
MA
CX
MCR-
VA
C
MA
CX
MCR-
VA
C
3.2
3.3
3.4
4.4
5.4
!
1
S1
8
PWR
ON
STA
T
1.1 1.2 1.3 1.4
3.1 3.2 3.3 3.4
+24V GND
I
OUT
GND
I
U
OUT
GND
U
24 V
120 V 170 V 250 V 370 V 550 V
N
80 V
54 V
36 V
1.3 1.4
3.1 3.2 3.3 3.4
5.4 5.3 5.2 5.1
4.4 4.3 4.2 4.1
OUT
IN
0
,
5
-
0
,
6
N
m
5
-
7
lb In
7
mm
A
WG
2
4-14
0
,
2
-
2
,
5
mm
2
M
A
CX
MCR
-...
A
B
A
A
B
8
mm
AWG 24-16
0,2-1,5
mm
2
MACX MCR-...-PT
DE
Einbauanweisung für den Elektroinstallateur
EN
Installation notes for electricians
2017-03-20
© PHOENIX CONTACT 2017
DNR 83161377 - 02
PNR 106308 - 02
DEUTSCH
DEUTSCH
ENGLISH
ENGLISH
5. Installation
IEC
61010-1:
Die Belegung der Anschlussklemmen zeigt das Blockschaltbild. (
)
Rasten Sie das Gerät im Schaltschrank auf eine 35
mm-Tragschiene nach EN
50022 auf. (
)
Die Einbaurichtung ist durch die Beschriftung auf dem Modul vorgegeben.
5.1
Spannungsversorgung
Die Spannungsversorgung (24
V
DC) des Moduls erfolgt an den Klemmen 1.3 und
1.4 (siehe Blockschaltbild).
ACHTUNG: Elektrostatische Entladung
Treffen Sie Schutzmaßnahmen gegen elektrostatische Entladung, bevor
Sie das Gerät bedienen oder installieren.
VORSICHT: Verletzungsgefahr
Stellen Sie sicher, dass Sie alle Modulstecker montieren, bevor Sie das
Gerät in Betrieb nehmen.
Ziehen Sie die Modulstecker nicht unter Last vom Gerät ab, um einen
Lichtbogen zu vermeiden.
VORSICHT: Verletzungsgefahr
Um Arbeiten unter gefährlicher Spannung zu vermeiden, setzen Sie zum
Abgleichen nur Quellen ein, die nach IEC
61010-1 6.3.1 nicht als
"GEFÄHRLICH AKTIV" gelten.
ACHTUNG
Bei Spannungsmessungen von <600
V (Überspannungskategorie II) oder
<300
V (Überspannungskategorie III) sind keine zusätzlichen
Sicherheitsabstände zu benachbarten Bauteilen erforderlich. In diesem Fall
besteht Basisisolierung.
Weitere Informationen zu Sicherheitsabständen finden Sie im zugehörigen
Datenblatt unter phoenixcontact.com.
•
Sehen Sie in der Nähe des Gerätes einen Schalter/Leistungsschalter
vor, der als Trennvorrichtung für dieses Gerät gekennzeichnet ist.
•
Sehen Sie eine Überstromschutzeinrichtung (I
16 A) in der Installation
vor.
•
Bauen Sie das Gerät zum Schutz gegen mechanische oder elektrische
Beschädigungen in ein entsprechendes Gehäuse mit einer geeigneten
Schutzart nach IEC
60529 ein.
•
Trennen Sie das Gerät bei Instandhaltungsarbeiten von allen wirksamen
Energiequellen.
•
Wenn das Gerät nicht entsprechend der Dokumentation benutzt wird,
kann der vorgesehene Schutz beeinträchtigt sein.
Voltage transducer (AC) for analog signals
1. Safety regulations
•
Installation, operation, and maintenance may only be carried out by qualified
electricians. Follow the installation instructions as described. When installing
and operating the device, the applicable regulations and safety directives
(including national safety directives), as well as generally approved technical
regulations, must be observed. The safety data is provided in this package slip
and on the certificates (conformity assessment, additional approvals where
applicable).
•
The device must not be opened or modified. Do not repair the device yourself,
replace it with an equivalent device. Repairs may only be carried out by the
manufacturer. The manufacturer is not liable for damage resulting from
violation.
•
The device is not designed for use in atmospheres with a danger of dust
explosions.
•
Once new configuration data has been written, the device performs a warm
start that changes the properties of the device. Adapt the following control
device to these modifications.
2. Short description
With the voltage transducer, you can record voltages in various measured value
ranges from 0
V
AC
...
24
V
AC to 0
V
AC
...
550
V
AC and convert them into
standardized analog signals.
The output signal (e.g.
0
...
20
mA) can be adjusted to the measured values of the
voltage input with the multi-function wheel (
, 3) to the maximum value (20
mA):
either by using the ZERO/SPAN configuration or the Teach-in configuration.
The device is calibrated ex-factory to 0
V
AC
...
24
V
AC on the input and
0
mA
...
20
mA on the output.
3. Operating and indicating elements
1
Supply voltage
2
Output: Standard signals
3
Multi-function wheel S2
4
Green “PWR” LED, power supply
5
LED red/green "STAT" status LED
6
DIP switch
7
Cover
8
Input: Measuring voltage
9
Snap-on foot for DIN rail mounting
4. Status and diagnostics indicators
You can download the latest documents at phoenixcontact.net/products.
NOTE
Ensure the specified distance between the voltage measurement input and
other conductive parts nearby is observed. This safety distance is required
to prevent electrical flashovers.
WARNING: Danger to life by electric shock!
The device is only to be used as described here. Phoenix Contact accepts
no liability if the device is used for anything other than its designated use.
Any use other than the designated use may lead to malfunction or
irreversible damage of the device.
The IP20 protection (IEC 60529/EN 60529) of the device is intended for use
in a clean and dry environment. Install the module in a housing with at least
IP54 degree of protection according to EN 60529. The stated limits
concerning mechanical or thermal loads on the module may not be
exceeded.
Cover termination area after installation in order to avoid accidental contact
with live parts (e. g., installation in control cabinet).
Warning! Read through the operating manual carefully.
Name
Color/status
Description
PWR
Green ON
Supply voltage present
Green flashing
Configuration mode
OFF
No supply voltage
STAT
Red ON
Internal error - replace the device
Flashing red
Values above or below the limits set on the output
Red flashing (3x)
Reset module to factory settings (configuration
mode)
Red flashing, fast
Operation error, incorrect configuration
Green ON
Change zero/span values (configuration mode)
Flashing green (3x)
Save configuration (configuration mode)
5. Installation
IEC
61010-1:
The assignment of the connection terminal blocks is shown in the block diagram.
(
)
Snap the device onto a 35
mm DIN rail according to EN 50022 in the control
cabinet. (
)
The installation direction is indicated by the marking on the module.
5.1
Power supply
The module is supplied with power (24
V
DC) via terminals 1.3 and 1.4 (see block
diagram).
NOTE: Electrostatic discharge
Take protective measures against electrostatic discharge before operating
or installing the device.
CAUTION: Risk of injury
Be sure to attach all module plugs before starting up the device.
To prevent an electric arc, do not disconnect the module plug from the
device under load.
CAUTION: Risk of injury
To avoid work under hazardous voltage, only use sources for calibration that
are not considered "HAZARDOUS ACTIVE" according to IEC
61010-1
6.3.1.
NOTE
For voltage measurements <600
V (overvoltage category II) or <300
V
(overvoltage category III), no additional safety distances from neighboring
components are necessary. Basic insulation exists in this case.
Further information on safety distances can be found in the associated data
sheet at phoenixcontact.com.
•
Provide a switch/circuit breaker close to the device, which is labeled as
the disconnecting device for this device.
•
Provide overcurrent protection (I
≤
16 A) within the installation.
•
To protect the device against mechanical or electrical damage, install it
in a suitable housing with appropriate degree of protection as per
IEC
60529.
•
During maintenance work, disconnect the device from all effective power
sources.
•
If the device is not used as described in the documentation, the intended
protection can be negatively affected.
Spannungsmessumformer (AC) für Analogsignale
1. Sicherheitsbestimmungen
•
Die Installation, Bedienung und Wartung ist von elektrotechnisch qualifiziertem
Fachpersonal durchzuführen. Befolgen Sie die beschriebenen
Installationsanweisungen. Halten Sie die für das Errichten und Betreiben
geltenden Bestimmungen und Sicherheitsvorschriften (auch nationale
Sicherheitsvorschriften), sowie die allgemein anerkannten Regeln der Technik
ein. Die sicherheitstechnischen Daten sind dieser Packungsbeilage und den
Zertifikaten (Konformitätsbewertung, ggf. weitere Approbationen) zu
entnehmen.
•
Öffnen oder Verändern des Geräts ist nicht zulässig. Reparieren Sie das Gerät
nicht selbst, sondern ersetzen Sie es durch ein gleichwertiges Gerät.
Reparaturen dürfen nur vom Hersteller vorgenommen werden. Der Hersteller
haftet nicht für Schäden aus Zuwiderhandlung.
•
Das Gerät ist nicht für den Einsatz in staubexplosionsgefährdeten
Atmosphären ausgelegt.
•
Nach dem Schreiben neuer Konfigurationsdaten führt das Gerät einen
Warmstart durch, durch den sich die Eigenschaften den Gerätes ändern.
Passen Sie das nachfolgende Steuergerät auf diese Änderungen an.
2. Kurzbeschreibung
Mit dem Spannungsmessumformer können Sie in verschiedenen
Messwertbereichen Spannungen von 0
V
AC
...
24
V
AC bis 0
V
AC
...
550
V
AC
erfassen und in normierte Analogsignale umsetzen.
Sie können das Ausgangssignal (z.
B. 0
...
20
mA) mit dem Multifunktionsrad (
,
3) an die Messwerte vom Spannungseingang auf den Maximalwert (20
mA)
anpassen: entweder mit der ZERO/SPAN-Konfiguration oder mit der Teach-In-
Konfiguration.
Das Gerät ist werksseitig auf 0
V
AC
...
24
V
AC am Eingang und 0
mA
...
20
mA
am Ausgang abgeglichen.
3. Bedien- und Anzeigeelemente
1
Versorgungsspannung
2
Ausgang: Normsignale
3
Multifunktionsrad S2
4
LED grün "PWR" Spannungsversorgung
5
LED rot/grün "STAT" Status-LED
6
DIP-Schalter
7
Abdeckung
8
Eingang: Messspannung
9
Rastfuß für Tragschienenmontage
4. Status- und Diagnoseanzeigen
Aktuelle Dokumente können unter der Adresse phoenixcontact.net/
products heruntergeladen werden.
ACHTUNG
Halten Sie die Abstandsvorgaben des Spannungsmesseingangs zu
anderen leitenden Teilen in der Umgebung ein. Dieser Sicherheitsabstand
ist erforderlich zur Vermeidung von elektrischen Überschlägen.
WARNUNG: Lebensgefahr durch Stromschlag!
Das Gerät ist ausschließlich für den hier beschriebenen Gebrauch
bestimmt. Bei nicht bestimmungsgemäßer Verwendung übernimmt
Phoenix Contact keine Haftung. Jegliche vom bestimmungsgemäßen
Gebrauch abweichende Verwendung könnte Fehlfunktionen oder
irreversible Schäden am Gerät verursachen.
Die Schutzart IP20 (IEC 60529/EN 60529) des Gerätes ist für eine saubere
und trockene Umgebung vorgesehen. Bauen Sie das Modul in ein Gehäuse
mindestens der Schutzart IP54 nach EN 60529 ein. Die beschriebenen
Grenzen für mechanische oder thermische Beanspruchungen des Moduls
dürfen nicht überschritten werden.
Nach der Installation den Klemmenbereich abdecken, um unzulässiges
Berühren spannungsführender Teile zu vermeiden (z. B. Einbau im
Schaltschrank).
Warnung! Lesen Sie die Bedienungsanleitung sorgfältig
durch.
Name
Farbe / Zustand
Beschreibung
PWR
Grün ein
Versorgungsspannung vorhanden
Grün blinkend
Konfigurationsmodus
Aus
Versorgungsspannung ist nicht vorhanden
STAT
Rot ein
Interner Fehler - tauschen Sie das Gerät aus
Rot blinkend
Über- oder Unterschreitung der eingestellten
Wertegrenzen am Ausgang
Rot blinkend (3x)
Modul auf Werkseinstellung setzen
(Konfigurationsmodus)
Rot blinkend
schnell
Bedienfehler, falsche Konfiguration
Grün ein
Zero/Span-Werte verändern
(Konfigurationsmodus)
Grün blinkend (3x) Konfiguration speichern (Konfigurationsmodus)