Troubleshooting
105555_en_07
PHOENIX CONTACT
25
English
Shaking out loose parts
•
Check if there are any loose parts in the device.
•
Shake the loose parts out of the device. Do not use any tool that
could damage the crimping tool.
•
If a conductor is still sticking in the device, remove it as de-
Checking waste guide plates
•
Check whether the two waste guide plates are undamaged.
•
If a waste guide plate is bent, you must replace it (see
Switching on the crimping tool
•
Reattach the service cover.
•
Press the ON button.
The yellow indicator light flashes.
If the yellow indicator light lights up
, follow the sequence for re-
lieving a blockage (see Page 22).
Inserting the taped ferrule
•
Check if the taped ferrule is damaged.
•
Detach damaged ferrules from the tape.
•
Re-insert the taped ferrule (see Page 13).
•
Reattach the waste container (see Page 13).
Loading the taped ferrule
•
Press the ON button.
You hear a sound of movement and the green indicator light
flashes. The crimping tool is ready for use.
If the yellow indicator light lights up
, follow the sequence for re-