Troubleshooting
105555_en_07
PHOENIX CONTACT
27
English
3.9
Replacing waste guide plates
3.9.1
Replacing waste guide plate GP1
Checking unit version
•
Check which type of waste guide plate is installed in your
crimping tool. You can only replace waste guide plates from
newer devices. Older devices must be sent to
Phoenix Contact. There the device is retrofitted to conform to
the current version.
Checking waste guide plates
•
Check whether the two waste guide plates are undamaged.
•
If a waste guide plate is bent, you must replace it.
–
Ordering data for the upper waste guide plate (GP2)
CF CRIMPHANDY 0.5/GP2, 1212515
CF CRIMPHANDY 0.75/GP2,1212516
CF CRIMPHANDY 1.0/GP2, 1212517
CF CRIMPHANDY 1.5/GP2, 1212844
–
Ordering data for the lower waste guide plate (GP1)
CF CRIMPHANDY/GP1,1212514
GP2
GP1
GP2
GP1
Removing residual insulation
•
Check if there is still residual insulation under waste guide plate
GP1.