Troubleshooting
105555_en_07
PHOENIX CONTACT
17
English
3.1
Overview of possible faults
Error
Cause
Solution
The device will not switch on
–
Problems with the power supply
–
Check the battery
–
Clean the battery compartment
The green indicator light
flashes, but the device does
not trip or the conductor can-
not be inserted
–
The battery was removed during a crimp-
ing cycle
–
Problems with the power supply
–
The conductor is not recognized
–
The crimping unit has been shifted manu-
ally
–
Initialize device (see Page 26)
The green indicator light
flashes, but there is still a con-
ductor in the device
–
The conductor was not correctly prepared
–
The conductor was inserted with too
much force
–
The conductor was pulled out too early
–
The conductor does not correspond to the
specifications
–
Carefully turn the conductor and pull
it out
–
The battery was removed during the
crimping process
–
Screw in the service tool and re-
move the conductor
–
Then initialize device (see Page 26)
The green and red indicator
lights flash slowly, but the con-
ductor is correct
–
The conductor is not recognized
–
The conductor is recognized as having an
incorrect cross-section
–
Switch off the device without the
conductor, and then switch on again
–
Check the stranding of the wires
–
Check if the conductor corresponds
to the specifications
–
Check the temperature range
Errors re-occur several times
–
The conductor does not correspond to the
specifications
–
Check if the conductor corresponds
to the specifications
–
Wear of the stripping blade
Indications for wear of the blade are rough
and asymmetrical cut edges on the insu-
lation remnants in the waste container
–
Please contact Phoenix Contact
–
The conductor was not correctly prepared
–
Prepare the conductor according to
specifications