GRAN BARISTO 07 DISASSEMBLY
7/10
Disconnect the electrical / idraulics connections.
7.10. Pump
Slip off the pump
off the support.
Remove the pump
extension.
7.11. Flow-meter
7.12. Gearmotor and microswitch present brew unit.
Lift the flow meter out of the casing assembly and remove the electrical and water circuit
connections.
Loosen the screws, unlock the pin and remove the system of levers.
In the reassembling make sure the spring is
repositioned correctly (see photo).