Service Modes, Error Codes, and Fault Finding
EN 26
SDI PDP 2K7
5.
Figure 5-9 Y-Main check points 42” HD W2 [2/5]
V
s
fu
s
e (F5001) –
OK
(0.x ~ x.x ohm)
V
s
fu
s
e (F5001) –
OPEN
(x.x Mohm)
15V fu
s
e (F500
3
) –
OK
(0.x ~ x.x ohm)
15V fu
s
e (F500
3
) –
OPEN
(x.x Mohm)
5V fu
s
e (F5004) –
OK
(0.x ~ x.x ohm)
5V fu
s
e (F5004) –
OPEN
(x.x Mohm)
V
s
et fu
s
e (F5005) –
OK
(0.x ~ x.x ohm)
V
s
et fu
s
e (F5005) –
OPEN
(x.x Mohm)
H_16
8
70_010.ep
s
040407
Vccf (F5006) –
OK
(0.x ~ x.x ohm)
Vccf (F5006) –
OPEN
(x.x Mohm)