Alignments
EN 66
SDI PDP 2K7
8.
8.1.5
Adjustment Power Supply Voltages 50" HD W2 Plus
Table 8-4 Adjustment voltage level overview (also refer to the sticker on the rear side of the panel)
Figure 8-11 Location of the voltage check points - 50” HD W2 Plus
No
Output voltage (V)
Voltage Setting (Normal Load)
Output Voltage Range
1
VS
207 V ± 1.5%
200 V
~
215 V
2
VA
63 V ± 1.5%
Fixed
3
VE
94 V ± 1.5%
105 V
~
115 V
4
VSCAN
-190 V ± 1.5%
-192 V
~
-188 V
5
VG
15 V ± 5%
Fixed
6
D5VL
5.3 V ± 5%
Fixed
Check voltage label on the PDP for correct values.
H_16
8
72_016.ep
s
191007