Alignments
EN 69
SDI PDP 2K7
8.
Figure 8-17 Adjusting waveforms - 42” HD W2 [1/2]
Figure 8-18 Adjusting waveforms - 42” HD W2 [2/2]
H_16870_069.eps
060407
VR5001
Adjustment : Rising Ramp
Oscilloscope Setting : 20V / 10us
VR5002
Adjustment : Falling Ramp
Oscilloscope Setting : 20V / 10us
H_16870_068.eps
060407
< Falling Ramp > <Rising Ramp>
Adjust VR5001 to set the time of Yrr
(Main Reset Rising Ramp) like the
below picture.
Oscilloscope Setting :
20V / 10us
Adjust VR5002 to set the time of Yfr
(Main Reset Falling Ramp) like the
below picture.
Oscilloscope Setting :
20V / 10us