![Philips S42AX-YD04 Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/philips/s42ax-yd04/s42ax-yd04_service-manual_1548490063.webp)
Alignments
EN 63
SDI PDP 2K7
8.
8.1.3
Adjustment Power Supply Voltages 42" HD W2 Plus
Table 8-2 Adjustment voltage level overview (also refer to the sticker on the rear side of the panel)
Figure 8-7 Location of voltage check points - 42” HD W2 Plus
No
Output voltage (V)
Voltage Setting (Normal Load)
Output Voltage Range
1
VS
205 V ± 1.5%
200 V
~
215 V
2
VA
63 V ± 1.5%
61 V
~
65 V
3
VE
99 V ± 1.5%
95 V
~
105 V
4
VSCAN
-190 V ± 1.5%
-195 V
~
-185 V
5
VG
15 V ± 5%
Fixed
6
D5VL
5.2 V ± 5%
Fixed
Check voltage label on the PDP for correct values.
H_16871_015.eps
070907