Service Modes, Error Codes, and Fault Finding
EN 18
FTL2.1, FTL2.2E AA
5.
Figure 5-3 Stepwise start-up part 1
Figure 5-4 Stepwise start-up part 2
Note (*)
:
•
When the set is in stepwise mode and, due to stepping-up,
a protection is activated, the set will really go into protection
(blinking LED). The set will not leave the stepwise-mode
however. If state X is the state where the set went to
protection, stepwise start-up will return to state X-1. At
state (X-1) diagnostic measurements can be performed.
Also, in the short time the set is in state X but not yet in
protection, you can also do some measurements.
5.4.4
How To Connect
This is described in the chassis fault finding database in
ComPair.
Figure 5-5 ComPair interface connection
5.4.5
How To Order
ComPair order codes (EU/AP/LATAM):
•
Starter kit ComPair32/SearchMan32 software and
ComPair interface (excl. transformer): 3122 785 90450.
•
ComPair interface (excl. transformer): 4822 727 21631.
•
Starter kit ComPair32 software (registration version): 3122
785 60040.
•
Starter kit SearchMan32 software: 3122 785 60050.
•
ComPair32 CD (update): 3122 785 60070 (year 2002),
3122 785 60110 (year 2003 onwards).
•
SearchMan32 CD (update): 3122 785 60080 (year 2002),
3122 785 60120 (year 2003), 3122 785 60130 (year 2004).
•
ComPair firmware upgrade IC: 3122 785 90510.
•
Transformer (non-UK): 4822 727 21632.
•
Transformer UK: 4822 727 21633.
•
ComPair interface cable: 3122 785 90004.
•
ComPair interface extension cable: 3139 131 03791.
•
ComPair UART interface cable: 3122 785 90630
Note:
If you encounter any problems, contact your local
support desk.
5.5
Error Codes
5.5.1
Introduction
The error code buffer contains all detected errors since the last
time the buffer was erased. The buffer is written from left to
right, new errors are logged at the left side, and all other errors
shift one position to the right.
When an error has occurred, the error is added to the list of
errors, provided the list is not full or the error is a protection
error.
When an error occurs and the error buffer is full, then the new
error is not added, and the error buffer stays intact (history is
maintained), except when the error is a protection error.
To prevent that an occasional error stays in the list forever, the
error is removed from the list after 50+ operation hours.
When multiple errors occur (errors occurred within a short time
span), there is a high probability that there is some relation
between them.
5.5.2
How to read the Error Buffer
Use one of the following methods:
•
On screen via the SAM (only if you have a picture).
Examples:
–
0 0 0 0 0
: No errors detected
–
6 0 0 0 0
: Error code 6 is the last and only detected
error
–
9 6 0 0 0
: Error code 6 was first detected and error code
9 is the last detected error
•
Via the blinking LED procedure (when you have no
picture). See next paragraph.
•
Via ComPair.
Initialize screen info
Start TXT acquisition
and time extraction
Reset Audio = low
and Initialize MSP
Screen type
400msec>t>200msec
Trapped Startup 2
+5V and +8V is switched on
Put Stand-by line LOW
CPU GO becomes HIGH
Keep sound amplifiers muted with
sound enable = high
+8V and +5V get their nominal level,
detected by the OTC
Read rest of NVM information
activate protection algorithms for +8V and +5V and
I²C (start I²C protection the moment the component
is initialised).
Initialize 3D Combfilter
or Initialize Columbus
Initialize HIP: IF, source selection, 2fh input, video
processing
Switch on the syncoutput: set_syncout_tristate= off
Stand-by
start time extraction
start P50 recording
start EPG loading
Standby bit = off
Ambient light ON
Initialize rest of PIP/DW module
Initialize tuner
Start up LCD
opt 3,4,5,6
Initialize PDP SDI
opt 0,1,7
E_14620_048.eps
170504
Initialize PDP FHP
opt 2,8
OFF
Read NVM identification
enable watchdog
OUT
OTC gets supply voltage
Mains cord IN
OTC resets, Initialise IO pins
Reset Audio=high
Tact switch
Stand-by bit = OFF
Set STBYEN,VCCON,PFCON = 1
Only FHP (opt 2, 8)
Initialize EBILD
Trapped Startup 1
Start
Semi stand by
yes
Ebild Power ON
Output Blanking OFF
ON
Stand-by bit set ?
no
Start up LCD
Trapped Startup 3
LAMP ON
LCD ON
Trapped Startup 4
E_14620_049.eps
170504
E_06532_021.eps
180804
PC
VCR
I2C
Power
9V DC
TO
UART SERVICE
CONNECTOR
TO
I2C SERVICE
CONNECTOR
Содержание FTL2.1E
Страница 94: ...94 FTL2 xE AA 7 Circuit Diagrams and PWB Layouts Layout SSB Top Side Part 1 Part 1 E_14620_053a eps 040105 ...
Страница 96: ...96 FTL2 xE AA 7 Circuit Diagrams and PWB Layouts Layout SSB Top Side Part 3 E_14620_053c eps 040105 Part 3 ...
Страница 97: ...Circuit Diagrams and PWB Layouts 97 FTL2 xE AA 7 Layout SSB Top Side Part 4 Part 4 E_14620_053d eps 040105 ...
Страница 100: ...100 FTL2 xE AA 7 Circuit Diagrams and PWB Layouts Layout SSB Bottom Side Part 1 Part 1 SAM SDM E_14620_054a eps 300305 ...
Страница 101: ...Circuit Diagrams and PWB Layouts 101 FTL2 xE AA 7 Layout SSB Bottom Side Part 2 Part 2 E_14620_054b eps 300305 ...
Страница 102: ...102 FTL2 xE AA 7 Circuit Diagrams and PWB Layouts Layout SSB Bottom Side Part 3 Part 3 E_14620_054c eps 300305 ...
Страница 103: ...Circuit Diagrams and PWB Layouts 103 FTL2 xE AA 7 Layout SSB Bottom Side Part 4 Part 4 E_14620_054d eps 300305 ...