background image

06-10-2020 14

:

42

Pagina 4 van 9

http://manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PST02-1B

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be 

added to an existing wireless network

 to communicate wi

devices of this network. This process is called 

Inclusion

.

Devices can also be removed from a network. This process is called 

Exclusion

. Both processes are initiated by the primary controller of the Z-Wave netwo

controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1.  Have Z-Wave Controller entered inclusion mode. 
2.  Pressing tamper key three times within 1.5 seconds to enter the inclusion mode. 
3.  After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.

Exclusion

1.  Have Z-Wave Controller entered exclusion mode. 
2.  Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. 
3.  Node ID has been excluded.

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The
and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out
Information Frame. To issue a NIF execute the following action: Press any key once, the device will awake 10 seconds.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In orde
communicate with the device, a static controller 

C

 is needed in the network. This controller will maintain a mailbox for the battery operated devices and store

commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time 
significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbo
Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static contro
controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses o
device. To wakeup the device please perform the following action: 

Press any key once, the device will awake 10 seconds.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

1.  Make sure a device is in factory reset state before including. In doubt exclude before include.
2.  If inclusion still fails, check if both devices use the same frequency.
3.  Remove all dead devices from associations. Otherwise you will see severe delays.
4.  Never use sleeping battery devices without a central controller.
5.  Dont poll FLIRS devices.
6.  Make sure to have enough mains powered device to benefit from the meshing

Firmware-Update over the Air

This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central controller. Once the controller sta
update process, perform the following action to confirm the firmware update: The device support the Z-Wave firmware update via OTA. Before starting the p
please remove the front cover of the device. Otherwise the hardware check will be failed. Let the controller into the firmware update mode, and then press t
tamper key once to start the update.  After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don"t remove the b
otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. C
After remove the battery, please wait about 30

seconds, and then re-install the battery.

Содержание PHI PST02-1B

Страница 1: ...t as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a device supports secure communication it will communicate with other devices sec...

Страница 2: ...set without any involvement of a Z Wave controller This procedure should only be used when the primary controller is inope 1 Pressing tamper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwis...

Страница 3: ...nds You will see the LED light ON one second Let the controller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the into the second group In the accessory pack There are two type of double coated tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter refe as B tape you can use A ...

Страница 4: ...ep state Without such a controller communication may become impossible and or the battery life time significantly decreased This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification The controller can then empty the mailbo Therefore the device needs to be configured with the desired wakeup interval and the node ID of the controller If the device wa...

Страница 5: ...us 256 For example To set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of a two byte value the same applies Values greater than 32768 may needed to be given as negative values too Parameter 2 Basic Set Level Setting the BASIC command value to turn on the light Size 1 Byte Default Value 255 Setting Description 0 turn off the light 1 100 the light strength 254...

Страница 6: ...tomer function switch using bit control Size 1 Byte Default Value 4 Setting Description 1 Reserve 2 Enable sending motion OFF report 0 Disable 1 Enable 4 Enable PIR super sensitivity mode 0 Disable 1 Enable 8 Reserve 16 Notification Type 0 Using Notification Report 1 Using Sensor Binary Report 32 Disable Multi CC in auto report 1 Disable 0 Enable 64 Disable to report battery state when the device tr...

Страница 7: ...27 Auto Report Temperature Time Parameter 20 Auto Report Tick Interval The interval time for auto report each tick Setting this configuration will effect configuration No 10 No 11 No 12 and No 13 Caution Setting to 0 means turn report function Size 1 Byte Default Value 30 Setting Description 0 255 Auto Report Tick Interval Parameter 21 Temperature Differential Report The temperature differential to ...

Страница 8: ...mware Update Md Manufacturer Specific Multi Command Sensor Multilevel Notification Powerlevel Security Version Wake Up Zwaveplus Info Controlled Command Classes Basic Explanation of Z Wave specific terms Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Controls or battery operated wall controllers Slave is a Z Wave device without capabili...

Страница 9: ...vice to announces that is able to communicate Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions c 2020 Z Wave Europe GmbH Antonstr 3 09337 Hohenstein Ernstthal Germany All rights reserved www zwave eu The template is maintained by Z Wave Europe GmbH The product content is maintained by Z Wave Europe GmbH Supportteam support zw...

Отзывы: