background image

 

 

Disposal   

 

This marking indicates that this product should not be disposed with other 
household wastes throughout the EU. To prevent possible harm to the 
environment or human health from uncontrolled waste disposal, recycle it 
responsibly to promote the sustainable reuse of material resources. To return 
your used device, please use the return and collection systems or contact the 
retailer where the product was purchased. They can take this product for 
environmental safe recycling

 

 

FCC Interference Statement 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules.   

These limits are designed to provide reasonable protection against harmful interference in a 

residential installation.   

This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio 

communications.   

However, there is no guarantee that interference will not occur in a particular installation.   

If this equipment does cause harmful interference to radio or television reception, which 

can be determined by turning the equipment off and on, the user is encouraged to try to correct 

the interference by one of the following measures: 

• Reorient or relocate the receiving antenna. 

• Increase the separation between the equipment and receiver. 

• Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected. 

• Consult the dealer or an experienced radio/TV technician for help. 

This device complies with Part 15 of the FCC Rules. Operation is subject 

to the following two conditions: 

(1) This device may not cause harmful interference, and 

(2) This device must accept any interference received, including interference that may cause 

undesired operation. 

FCC Caution: Any changes or modifications not expressly approved by the party responsible 

for compliance could void the user's authority to operate this equipment. 

This transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter. 

 

Содержание PAN24

Страница 1: ...sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your sit...

Страница 2: ...ton again and hold for 5 seconds 3 IDs are excluded LED 2 second on 2 second off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification S...

Страница 3: ... off the switch will turn off Programming 1 Basic Command Class Binary Switch Command Class PAN24 will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Upon receipt of the following commands from a Z Wave Controller PAN24 will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report ...

Страница 4: ... Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF 2 2 Response to Meter Get Command The switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH or 3 AC load Voltage V or 4 AC load current I 5 load power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller ...

Страница 5: ...ision 2 Scale 5 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 Bytes I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter R...

Страница 6: ...he Range of the setting value is from 10 to 1500 and the default value is 1500 3 6 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value If the setting value is 10000 when the Accumulated Power Consumption of Relay1 over this value PAN24 will send KWH meter report to warn the Group1 node minimum value is 1KWh and default value is 10000 kWh 3 7 Wat...

Страница 7: ...Temperature 0 C 40 C 85 humidity Storage Temperature 20 C 60 C Location Indoor use only Frequency Range 868 40MHz 869 85MHz EU 908 40MHz 916 00MHz USA Canada 916MHz Israel Specifications are subject to change and improvement without notice FCC ID RHHPAN24 www philio tech com Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan Warning 1 Plug out to di...

Страница 8: ...cations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation...

Отзывы: