Philio PAN24 Скачать руководство пользователя страница 2

 

 

Function 

Description 

Annotation 

No node ID 

The Z-Wave Controller does not 
allocate a node ID to the Switch. 

LED 2-second on, 
2-second off 

Add

 

1.Put your Z-Wave controller into 

 

inclusion mode by following the 

 

instructions provided by the 

 

controller manufacturer. 

 

 
 
 
 
 
 
 
 
 
  “

”LED blink three times.

 

 

2. Press and hold “

” button first,

 

        then press “

” button three times

 

      within 2 seconds will enter inclusion

 

      mode.

 

Remove

 

1.Put your Z-Wave controller into 

 

exclusion mode by following the 

 

instructions provided by the 

 

controller manufacturer.

 

 
 
 
 
 
 
 
 
 

”LED blink three times.

 

2. Press and hold “

” button first,

 

        then press “

” button three times

 

        within 2 seconds will enter exclusion

 

        mode.

 

3. Node ID has been excluded.

 

 

Reset

 

1. Press and hold “

” button first,

 

        then press “

” button three times

 

        within 2 seconds will enter inclusion

 

        mode.

 

Use this procedure only in 

 

the event that the primary 

 

controller is lost or 

 

otherwise inoperable.

 

2.Within 1 second, press “

” button 

again and hold for 5 seconds.

 

3. IDs are excluded.

 

LED 2-second on, 2-second 
off

 

Adding a node ID allocated by Z-Wave Controller means inclusion.    Removing a node

 

ID allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

 

 
LED Indication

 

To distinguish what mode the switch is in, view from the LED for identification.

 

 

State Type

 

LED Indication

 

Normal

 

Under normal operation, short pressing 

  “

 button will turn On and 

Off. When switch turns on, green LED lights up, whereas turns off, 
red LED is lights up.

 

No node ID

 

Under normal operation, when the Switch has not been allocated a 
node ID, the 

  “

 LED flashes on and off alternately at 2-second 

intervals. 

 

Learning

 

When PAN24 enter include or exclude mode by pressing the 
combination of 

  “

” button and “

” button 

 LED will flashes 

three times 0.5 second intervals.

 

Overload

 

When overload state occurs, the switch is disabled of which 

 

LED flashes on and off alternately at 0.2 second intervals. Overload 
state can be cleared by disconnecting and reconnecting the Switch 
to the wall outlet.

 

 

 

 
Overview   
 
 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

Содержание PAN24

Страница 1: ...sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your sit...

Страница 2: ...ton again and hold for 5 seconds 3 IDs are excluded LED 2 second on 2 second off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification S...

Страница 3: ... off the switch will turn off Programming 1 Basic Command Class Binary Switch Command Class PAN24 will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Upon receipt of the following commands from a Z Wave Controller PAN24 will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report ...

Страница 4: ... Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF 2 2 Response to Meter Get Command The switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH or 3 AC load Voltage V or 4 AC load current I 5 load power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller ...

Страница 5: ...ision 2 Scale 5 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 Bytes I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter R...

Страница 6: ...he Range of the setting value is from 10 to 1500 and the default value is 1500 3 6 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value If the setting value is 10000 when the Accumulated Power Consumption of Relay1 over this value PAN24 will send KWH meter report to warn the Group1 node minimum value is 1KWh and default value is 10000 kWh 3 7 Wat...

Страница 7: ...Temperature 0 C 40 C 85 humidity Storage Temperature 20 C 60 C Location Indoor use only Frequency Range 868 40MHz 869 85MHz EU 908 40MHz 916 00MHz USA Canada 916MHz Israel Specifications are subject to change and improvement without notice FCC ID RHHPAN24 www philio tech com Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan Warning 1 Plug out to di...

Страница 8: ...cations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation...