Installation and Operation

 

 

1.  Plug this switch into a wall box near the load to be controlled. 

2.  Connects  the  load  to  the  switch.  Make  sure  the  load  to  be  controlled  cannot 

exceed 16A (Resistive Load). 

3.  Press the button or switch on the load to the ON position. 

4.  To manually turn ON the switch, short press the “

” button. The green “

” LED 

will turn ON, and the blue timer LEDs will also turn ON. Every passed 10 minutes 

will change one blue LED as a green LED. When all the blue LEDs changes, all 

the green LEDs will blink twice and turn off. Then the switch turns off and green 

” LED changes to red “

” LED. 

5.  To manually  turn  OFF  the  Switch,  short  press  the  “

”  button.  The  red  LED  will 

turn ON and the load connected to the switch will also turn OFF. 

6.  Every short press “

” button, there will be increasing one more blue LED. When 

arrives to the intended timer, stop pressing and all the blue LEDs will blink twice. 

Or you can press and hold “

” button, there will be increasing one more blue LED 

every half second. Every blue LED represents 10 minutes working time of switch. 

The maximum time is 110 minutes, and the default is 60 minutes.   

7.  Every short press “

” button, there will be decreasing one blue LED. This means 

the working time of switch decrease 10 minutes. The minimum time is 10 minutes. 

Or  you  can  press  and  hold  “

”  button,  there  will  be  decreasing  one  blue  LED 

every half second.

 

8.  After  switch  is  turned  on  for  a  while,  you  can  still  decrease  (or  increase)  the 

working  time  by  pressing  “

”  button  (or  “

”  button).  When  all  the  blue  LEDs 

decreases to off, the switch will turn off.

 

 

Programming

 

 

1.    Basic Command Class / Binary Switch Command Class

 

PAN24  will  respond  to  BASIC  and  BINARY  commands  that  are  part  of  the 
Z-Wave system.

 

 

1-1 BASIC_GET / BINARY_SWITCH_GET

 

        Upon  receipt  of  the  following  commands  from  a  Z-Wave  Controller,  PAN24  will 

report its On/Off state to the node asked.

 

 

Basic Get Command: [Command Class Basic, Basic Get]

 

Basic Report Command:

 

Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]

 

Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]

 

 

Binary  Switch  Get  Command:[Command  Class  Switch  Binary,  Switch  Binary 
Get]

 

Binary Switch Report Command:

 

Report OFF:[Command Class Switch Binary, Switch Binary Report, Value 
=0(0x00)]

 

Report ON:[Command Class Switch Binary, Switch Binary Report, Value = 
255(0xFF)]

 

 

1-2 BASIC_SET / SWITCH_BINARY_SET

 

        Upon  receipt  of  the  following  commands  from  a  Z-Wave  Controller,  the  load 

attached to PAN24 will turn on or off.

 

 

[Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)]: the load attached 
to the switch turns on.

 

[Command  Class  Basic,  Basic  Set,  Value  =  0(0x00)]:  the  load  attached  to  the 
switch turns off.

 

[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  1~99,  (255)0xFF]: 
the load attached to the switch turns on. 
[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  0(0x00)]:  the  load 
attached to the switch turns off. 

 
1.  Z-Wave’s Groups (Association Command Class Version 2) 
 

The  Switch  can  be  set  to  send  reports  to  associated  Z-Wave  devices.    It  supports 

one association group with one node support for Grouping 1. For group 1, the Switch 

will report its latest status to Z-Wave Controller.   
 
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, 
ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION. 
 

2-1 Auto report to Grouping 1 (Maximum Node 5) 

Содержание PAN24

Страница 1: ...sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your sit...

Страница 2: ...ton again and hold for 5 seconds 3 IDs are excluded LED 2 second on 2 second off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification S...

Страница 3: ... off the switch will turn off Programming 1 Basic Command Class Binary Switch Command Class PAN24 will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Upon receipt of the following commands from a Z Wave Controller PAN24 will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report ...

Страница 4: ... Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF 2 2 Response to Meter Get Command The switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH or 3 AC load Voltage V or 4 AC load current I 5 load power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller ...

Страница 5: ...ision 2 Scale 5 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 Bytes I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter R...

Страница 6: ...he Range of the setting value is from 10 to 1500 and the default value is 1500 3 6 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value If the setting value is 10000 when the Accumulated Power Consumption of Relay1 over this value PAN24 will send KWH meter report to warn the Group1 node minimum value is 1KWh and default value is 10000 kWh 3 7 Wat...

Страница 7: ...Temperature 0 C 40 C 85 humidity Storage Temperature 20 C 60 C Location Indoor use only Frequency Range 868 40MHz 869 85MHz EU 908 40MHz 916 00MHz USA Canada 916MHz Israel Specifications are subject to change and improvement without notice FCC ID RHHPAN24 www philio tech com Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan Warning 1 Plug out to di...

Страница 8: ...cations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation...

Отзывы: