7
Troubleshooting
Symptom
Cause of Failure
Recommendation
The switch does not
work and the LED is off
1.
The Switch is not
plugged into the
electrical outlet
properly
2.
The Switch break
down
1. Check power connections
2. Don’t open up the Switch and send
it for repair.
The LED illuminates, but
cannot turn ON or OFF
the
switch
1. Check if the load
plugged into the
Switch has its own
ON/OFF switch
2. Not carry out
association
3. Same frequency
interference
1. Set the ON/OFF switch of the load
attached to ON
2. Carry out association
3.Wait for a while to re-try
LED keep flashing, but
cannot control
Overload occurs
Remove the load attached or check
max. load cannot exceed 16.0A
Specification
Operating Voltage
100-240VAC 50/60Hz 16A
Rated Voltage
220-240Vac 50Hz (EU), 120Vac 60Hz (US), 230Vac 50Hz (IL),
100Vac 50/60Hz (JP)
Maximum Load
16A (Resistive Load)
Range
Minimum 40M in door and 100M in outdoor line of sight
Operating Temperature
0°C ~ 40°C (85% humidity)
Storage Temperature -20 C ~ 60°C
Location
Indoor use only
Frequency Range
868.40MHz; 869.85MHz(EU)
908.40MHz; 916.00MHz(USA/Canada)
916MHz (Israel)
** Specifications are subject to change and improvement without notice.
FCC ID : RHHPAN24
www.philio-tech.com
Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan
Warning:
1.Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating
Choosing a Suitable Location
1. Do not locate the switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source of
heat, e.g. fires, radiators, switch etc.
4. After putting it into use, the body of switch will become a little bit hot of which
phenomenon is normal.
DANGER
Danger of electrocution!
All works on the device may be performed only by a qualified and licensed electrician.
Observe national regulations.
Any works introducing changes into the configuration must be always performed with
disconnected voltage.