background image

     Any changes or modifications not expressly approved by the 
party responsible for compliance
could void the user's authority to operate the equipment.
    NOTE: This equipment generates, uses and can radiate radio 
frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular 
installation.
    If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the

 

interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.

 

-- Connect the equipment into an outlet on a circuit different from 
that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF Exposure guidelines, This 

equipment should be installed and operated with minimum distance 

between 20cm the radiator your body: Use only the supplied antenna.

FCC ID: 2AIT9-PG101

Содержание CT-PG-100

Страница 1: ...GSM anti theft alarm controller User manual App Store Android Scan here download and install APP QR code 99 8 DEFENSE ZONES...

Страница 2: ...GSM anti theft alarm controller...

Страница 3: ...ge Setting 19 Host Keypad Lock Setting 20 Host Timing Arm Disarm Enable Disable Setting 21 Host Timing Arm Disarm Setting 22 Host Reset Setting 23 Host Logs Inquires 3 4 5 7 8 9 9 9 9 9 10 10 11 11 12...

Страница 4: ...d be coded with smart home appliance Arm and Disarm timing function Can store 6 groups of phone numbers when alarming system will make alarm call to these numbers automatically Can store 2 groups of S...

Страница 5: ...3 Z4 GND Z5 Z6 GND Z7 Z8 GND NO Arm Disarm GSM anti theft alarm controller GSM anti theft alarm controller Alarm Host Installation Power indicator light Arm indicator Alarm indicator SOS LCD Arm Disar...

Страница 6: ...talled apposite the transmitter the distance between them should not be more than 1 cm 3 After installation the indicator light flashes one second while opening the door which means installation is av...

Страница 7: ...ration the host would make a tick sound and setting is finished Operating method press button 4 Coding of Remote Controller Setting In setup state input number 21 then press to confirm The host make a...

Страница 8: ...sensor for zone would be invalid so think it over before deleting Operating method 25 LCD display 9 Alarm Type Setting 9 1 There are 4 Defense Types Detector alarm type is set to 0 This detector will...

Страница 9: ...r Stay Arm Operating method 47 82 1 LCD display 10 Wireless Siren Coding Setting In setup state input 28 8 digit wireless siren coding then enter to confirm The host makes a tick sound and then a voic...

Страница 10: ...dicates Delayed alarm time unit second Example Detailed operating of 5 seconds delayed alarm time for defense zone 05 Operating method 34 05 05 LCD display 13 Arm Time Delay Setting In setup status en...

Страница 11: ...XXXX indicates the new 4 digit password Example change the system password to 1012 Operating 38 1012 LCD display 18 2Change Administrator Password In setup status use keypad to input 39 then input the...

Страница 12: ...B XXYY AABB indicates disarming time hour and minute XXYY indicates arming time hour and minute Example set disarming to 8 20 and arming time to 20 30 Operating 42 0820 2030 LCD display 20 Host Timing...

Страница 13: ...hen a voice prompts setting completed Default not send Operating 46 X X 1 indicates send X 0 indicates not send Example send out SMS to user s mobile phone Operating 46 1 LCD display 26 System Clock S...

Страница 14: ...makes a tick sound and then a voice prompts setting completed Operating 49 Example Deleting the first SMS alarm phone number Operating 49 LCD display 29 Alarm Phone Number Setting In setup state ente...

Страница 15: ...SOS Alarm 2 fire alarm 3 gas leak alarm 4 door lock alarm 5 hall alarm 6 window alarm 7 balcony alarm 8 perimeter alarm Example set defense zone 10 to be fire alarm type Operating 60 10 2 LCD display...

Страница 16: ...ing completed Default level 6 Operating method 64 X X indicates volume level Example level 2 Operating 64 2 Note If the volume level is set 0 then no sound LCD display 35 Language Setting In setup sta...

Страница 17: ...ace operation Press the pr set host account enter into Main Menu then user can operate the functions of disarm out arm stay arm dial back and monitor and so on Press the pr set host account enter Syst...

Страница 18: ...m state Disarm Press key host releases prompt System disarmed Disarm indicator LED on all the defense zones enter into Disarm state Press key host releases prompt System armed Out Arm indicator LED on...

Страница 19: ...voice alarm If no one answers the call the system will call the next user number automatically The system will call each preset numbers for 3 times in order If you answer the call you will hear the p...

Страница 20: ...lephone numbers 3 Whether the detector signal is received or backup battery works 3 Sensor detection 1 Manually trigger the detector to check whether it make alarms as usual 2 Check batteries of all d...

Страница 21: ...ing Function Setting Host Timing Arm Disarm Setting Host Reset Setting Host Logs Inquires System Clock Setting SMS Phone Number Setting LCD Backlight Time Setting Sound Volume Setting Language Setting...

Страница 22: ...ence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reo...