3)7*67$1'$5'
86$
&KHFNOLVW
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
________________________________________________________________________________________
)DXOW
&DXVH
6ROXWLRQ
Pump motor does not start
- Pump motor defective
Correct faults
- Connection cable defective
- Plug or integrated socket
- defective
- Motor protection switch defective or
triggered
Stoppage after a short time
- Dirt collection filter dirty
Clean or replace filters and
- Pressure reducer filter dirty
- Hose connection or water pipe
increase water connection size
- too small
- Water vessel suction pipe too weak
or too long
Machine does not switch off
- Air pressure safety switch
- Adjust air pressure switch
- Air wrongly adjusted or
- Replace air hose or check
compressor
- defective
- Air hose defective
- Air tap on spray gun
- defective
- Compressor provides too
- little air
- Air pipe on compressor
- not connected
Mortar flow stops
- Poor mixture in mixing tube
Add more water
- Mixing shaft defective
If this does not help, clean
- Motor hauling bracket
or replace mixing shaft
- defective
- Input hopper to mixing
Dry mixing tube inlet and
- tube wet; material clumped
star again
- mixing tube inlet restricted!
Mortar flow "thick-thin"
- Too little water
If there is too little water
- Water safety switch wrongly adjusted
or defective
increase water quantity by 10 % for
approx. 1/2 minute
- Mixing shaft defective; no original PFT
mixing shaft
then return slowly to normal setting
- Pressure reducing valve wrongly
adjusted or defective
or tighten or replace pump parts
- Stator worn, defective Rotor worn or
not tight enough
- Clamp defective (oval)
- Pressure flange almost blocked
- Mortar hose inner wall defective
Correct other faults