6HWWLQJXSWKHPDFKLQH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
________________________________________________________________________________________
The machine must always only be connected to an electrical panel with a 32 A FI
protective switch conforming to regulations. The connection cable must conform to the
version H07 RN-F 5 x 4,0 mm². If there is a 5-pin connection, the fused sockets for the
connection of water pump, hand lamp etc. are available.
As a general principle, we recommend use of the PFT power cable 5 x 4,0 mm², 50 m,
with plug and coupling (Part no. 20 42 39 00).
Before the control box is supplied with electricity, the following points must be adhered
to:
- Switch off main switch (1) ("0") position lockable).
- Turn the star wheel switch (2) to the "0" position.
- Turn the dummy plug.
Switch off the compressor.
Connect power supply cable to control box.