3)7*67$1'$5'
86$
&KHFNOLVW
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
________________________________________________________________________________________
+RZFDQSUREOHPVZLWKWKH3)7*6WDQGDUGEHDYRLGHGRUTXLFNO\FRUUHFWHG"
)DXOW
&DXVH
6ROXWLRQ
Machine does not start!
:DWHU
- Check water supply
Water pressure too low -
- Clean dirt collection filters
Gauge shows less than 2,5 bar
- Turn the switch of water pump to
automatic
Machine does not start!
3RZHU
- Power supply correct?
Corrects faults
- Correct connection to electrical
panel?
- FI protection switch activated?
- Main switch switched on?
- Pole reversal switch on?
- Fault lamp lit?
- Motor protection switch activated?
- Self-latching button not pressed?
- Protector defective?
- Fuse defective?
- Water protection switch wrongly
adjusted?
- Pump blocked?
Machine does not start!
$LU
Correct faults and clean
- Insufficient pressure gradient
blocked air pipe or air
- in remote controller due to
nozzle tube!
- blocked air pipe or air nozzle
- tube?
- Air safety switch wrongly adjusted?
- Compressor
connected
and
switched on?
Machine does not start!
0DWHULDO
Correct faults, perhaps half
- Too much thick material in
empty hopper and start up
- hopper or mixing zone?
again.
- Material in pump tube too dry
&$87,21
First switch off main switch and pull
out plug.
Water does not flow
- Solenoid valve (hole in
Correct faults
- membrane blocked)
- Magnetic coil defective
- Pressure reducing valve closed
- Water inlet on pump tube blocked
- Needle valve closed
- Cable to solenoid valve defective
Содержание PFT G4