3)7*67$1'$5'
86$
6HWWLQJXSWKHPDFKLQH
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
________________________________________________________________________________________
Lock the lockable lever before setting up and starting the machine.
Connect the water system with a 3/4" hose. Open the water valve on the air-water
manifold to bleed the water hose. Close the water valve.
If the water pressure falls below 2,5 bar, the PFT pressure booster pump (art. no.
00 00 11 40) must be switched into the supply. If a water pump is being used it can, if
there is sufficient static pre-pressure, be connected to the wired connector 230 V (!)
(grey). This prevents the pump being switched off through overheating when it
operates against closed valves (e.g. after a long pause).
127(
If the prior water pressure is too low or the pump is working out of the water vessel,
the water pump can be connected to the blue continuous current socket 230 V (2)
(blue).
:$51,1*
In case of longer working breaks unplug to avoid overheating of water pressure
booster pump.
:$51,1*
When using water out of a barrel use section inlet with filter (Part no. 20 47 50 00).
Ventilate water pump.