Putting the machine into operation
2017-01-16
27
20.3 Changing the direction of rotation at the main switch
Fig. 36: Changing the direction of rotation
DANGER!
Danger of death due to unauthorised restarting!
When working on the machine, there is a danger of
unauthorised switching on of the electrical supply.
This puts those in the danger area at extreme risk.
– Before starting work, switch off all electrical
power supplies.
1. Remove the power cord (1) from the main switch (2).
Fig. 37: Turning the contacts
2. Turn the phase inverter (3) in the plug by pressing with
a screwdriver.
3. Turn the contacts with the screwdriver.
4. Reconnect the power supply.
5. Turn the main switch to the “I” position.
Fig. 38: Material consistency
6. Check the material consistency at the mortar outlet.
2
1
3