PFT LOTUS XL light 400 V Overview – Operation – Spare Parts Lists
Preparation of the machine
2017-01-16
23
18.1 Fastening the LOTUS XL to the silo
Fig. 24: Connection
1. Fasten the LOTUS XL to the silo/container with the assembly aid.
NOTE!
When assembling, ensure that the rubber gasket is not
damaged.
18.2 Connection to the 400 V power supply
Fig. 25
: Electrical connection 400 V
1. Only connect the machine (1) to three-phase current with 400 V.
DANGER!
Danger of death due to electric current!
The electrical connection must be fused
correctly:
Only connect the machine to a power source
with an approved FI circuit breaker (30 mA)
RCD (residual current device) of type “A”.
18.3 Checking the individual connector plugs
1
2
3
Fig. 26
: Electrical connections
Connect the water pump (1).
NOTE!
The booster pump is necessary if the water
pressure falls below 2.5 bar during running
operation of the machine.
Check the connection of the vibrator (2).
Check the connection of the mixer motor (3).
WARNING!
Danger of death due to rotating parts!
Improper operation can lead to serious injuries
or equipment damage.
The respective drives (motors) may only be
operated through the corresponding control
unit of the machine.
1
1