23.2 End of shift / Cleaning
Fig. 39: Closing the silo outlet flap
1. Shortly before the end of work, close the silo outlet flap (1) and
run the machine empty until extremely diluted mortar emerges.
23.3 Switching off the machine
Fig. 40: Switching off the machine
1. Turn the main switch (1) to the position “0”.
2. Remove the power cord (2) from the main switch.
23.4 Removing the mixing tube
2
1
Fig. 41: Removing the mixing tube
1. Disconnect the water supply from the middle body (1).
2. Release the flanged nuts (2) on both sides and take off
the mixing tube.
Fig. 42: Cleaning
5. Clean the mixing tube (3), rubber mixing tube (4), mortar outlet (5)
and rubber outer bearing (6).
6. Clean the mixing shaft with dosing segment (7).
DANGER!
Danger of death due to unauthorised restarting!
When cleaning the machine, allow no water
to penetrate into the electrical components.
NOTE!
When assembling the components, make certain
they are clean and dry.
Always keep eyebolts and gaskets in clean condition.
Grease bearing journals and connection points
of the mixing shaft.
1
2
3
4
7
1
6
5