Mixing pump RITMO L Eco Overview - Operation
Switching off RITMO L Eco
58
12 April 2019 13:43:00
47.9 Cleaning the mixing tube
Fig. 89: Cleaning
1. Close the protection grille with motor (1).
2. Firmly tighten the nuts (2) at the protection grille.
3. Insert 10-pin connector (3).
4. Turn the selector switch (4) clockwise to position "FWD".
5. Let the machine run for about 5 - 10 seconds until the mixing tube
has been cleaned.
6. Turn the selector switch (4) to “0” position (middle position).
7. Remove the 10-pin connector (3).
8. Loosen the nuts (2) at the protection grille and tilt backwards.
9. Take the mixing tube cleaner with cleaning shaft from the material
hopper.
47.10 Close the protection grille with motor
Fig. 90: Fit of the mixing shaft
NOTE!
When inserting the mixing shaft (1)
ensure that the mixing shaft engages
with the head of the rotor (2) and grips
properly into the hauling bracket (3)
when closing the motor flange.
48 Switching off RITMO L Eco
1
2
3
Fig. 91: Switching off the machine
1. Turn the selector switch (1) to “0” position (middle position).
2. Open the cover (2) of the on/off switch.
3. Press the red push-button (3) for “OFF” mode.
4. Close cover (2) of the on/off switch.
1
3
2
4
1
2
3