Mixing pump RITMO L Eco Overview - Operation
Apply mortar
12 April 2019 13:43:00
41
NOTE!
The possible conveying distance depends mainly
on the flowability of the mortar. Heavy, sharp-
edged mortar has poor flow characteristics. Runny
materials have good flow characteristics.
If 20 bar operating pressure are exceeded the hose
length must be reduced.
38.1 Open the air tap at the spraying gun
1
Fig. 61: Opening the air tap
1. Aim the spray gun at the wall to be plastered.
2. Ensure that nobody is in the discharge area of the spraying
gun.
3. Open the air tap (1) at the spraying gun.
4. The machine will start-up automatically via the pressure switch-
off and the mortar emerges at the spraying gun.
NOTE!
The correct mortar consistency is reached, if the
material mixes on the surface to be sprayed (we
recommend application on wall surfaces from top
to bottom). If the water quantity is too little even
mixing and spraying is no longer guaranteed;
blockages may form inside the hose and high wear
of the pump parts will become an issue.
NOTE!
It is also possible to operate the machine without
compressed air, e.g. for filling screed. To this end,
pull the connector of the air compressor and
operated without the spraying gun. Switch the
machine on or off via the selector switch.
38.2 Interruption of work
NOTE!
Always observe the setting time of the material to be
processed:
Clean the system and mortar hoses depending on
the setting time of the material and the length of the
interruption (pay attention to outside temperature).
The guidelines of the material manufacturers have
to be observed regarding breaks.