5.3 Anchor pumping station
CAUTION
Danger of injury due to the pumping station tipping or rolling away
Superstructural parts change the center of gravity. There is a danger of crushing due to rolling away
or tipping.
► Place the pumping station on a flat installation surface.
► Anchor the pumping station at the installation location.
► Wear personal protective equipment.
Anchor pumping station
The operator is responsible for anchoring.
● Make sure that the operator-installed pumping station housing fixation absorbs the tor-
que that occurs in case the turbopump rotor blocks suddenly.
Required aids
● 3x lashing straps of adequate length and loading capacity; width approximately 3 cm
● On-site attachment points to retain the lashing straps
1
2
3x
Fig. 7:
Fix pumping station with lashing straps
1 Mounting hooks (3×)
2
Lashing strap
Secure pumping station against twisting
1. Always fix the pumping station with lashing straps on all three mounting hooks.
– Observe max. load of 2000 N per mounting point.
2. Affix the lashing straps perpendicularly to the mounting hooks opening, i.e., against the turbo-
pump rotation direction.
3. Make sure that the belts are fitted and tensioned correctly. Make sure that the belt loop is in the
hollow of the mounting hook.