background image

Display Back-Light Button: Press ( 

 ) button to toggle 

between turn on and turn off the Back-Light. 
Laser Marker Button: Press ( 

 ) button to toggle 

between turn on and turn off the Laser Marker 
annunciator and laser marker beam. Measure Button: 
Depress button (6) to turn on the meter for measuring 
temperature. Release the button to stop measuring 
temperature and automatically hold the display reading, 
the meter turns off automatically after 15 seconds.
Auxiliary output: The microphono jack (2.5 mm) 
connector output (4) is active as long as the light meter is 
turned on.

MEASURING PROCEDURES

1.  When the power is off, pressing the (6) button turns on 

the power.

2.  Use ( 

 ) button to select turn on or turn off the 

display Back-Light.

3. Use ( 

 ) button to select turn on or turn off the Laser Marker.

4.  Point the lens at the object whose temperature is to be 

measured.

5.  Press the (6) button. The display is updated as long as 

the (6) button is kept pressed.

6.  Aim the laser beam at the object whose temperature is 

to be measured.

NOTE: Although the field of measurement (or Field of 
View) and the spot almost coincide, actually the field 
of measurement corresponds to the diameter for 90% 
optical response. The object whose temperature is to 
be measured needs to be larger than the measurement 
diameter (spot of size) by an adequate margin at least 1.5 
to 2 times larger.
7. Read the display.

MAINTENANCE

In Case of Difficulties: In the case of improper operation of the thermometer, first 
review the operating instructions for possible errors in operation. Check the condition 
of the batteries. The battery “ 

 ” symbol appears when the voltage falls below the 

level where accuracy is guaranteed. Replace the batteries immediately.

Battery Replacement
To replace the batteries ( 4 – AAA) unscrew the battery hatch screw and remove the 
old batteries. Install the new batteries observing the diagram in the battery area.
Cleaning Procedure
Gently wipe dirt from the surface of the unit with a soft cloth moistened with 
a small amount of water or neutral cleanser. Do not use benzene, alcohol, 
acetone, ether, paint thinner, lacquer or ketone solvents on the units, under any 
circumstances as these may cause deformation or discoloration.

REPAIR

Read the warranty located at the front of this manual before requesting warranty or 
nonwarranty repairs. For warranty repairs, any thermometer claimed to be defective 
can be returned to any Amprobe Test Tools authorized distributor or to a Amprobe 
Test Tools Service Center for an over-the-counter exchange for the same or like 
product. Nonwarranty repairs should be sent to a Amprobe Test Tools Service Center. 
Please call Amprobe Test Tools or enquire at your point of purchase for the nearest 
location and current repair rates. All thermometers returned for warranty or non-
warranty repair or for calibration should be accompanied by the following information 
or items: company name, customer’s name, address, telephone number, proof of 
purchase (warranty repairs), a brief description of the problem or the service requested, 
and the appropriate service charge (for non-warranty repairs). Service charges should 
be remitted in the form of a check, a money order, credit card with expiration date, or 
a purchase order made payable to Amprobe Test Tools or to the specific service center. 
For minimum turn-around time on out-of-warranty repairs please phone in advance 
for service charge rates. The thermometer should be shipped with transportation 
charges prepaid to one of the following addresses or to a service center:

IR610A Operating Instructions 

P/N 1638847

Limited Warranty and Limitation of Liability

Your Amprobe product will be free from defects in material and workmanship for 
1 year from the date of purchase. This warranty does not cover fuses, disposable 
batteries or damage from accident, neglect, misuse, alteration, contamination, 
or abnormal conditions of operation or handling. Resellers are not authorized 
to extend any other warranty on Amprobe’s behalf. To obtain service during the 
warranty period, return the product with proof of purchase to an authorized 
Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See 
Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER 
WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED 
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, 
ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY 
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, 
ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not 
allow the exclusion or limitation of an implied warranty or of incidental or 
consequential damages, this limitation of liability may not apply to you.

CERTIFICATIONS AND PRECAUTIONS

• The IR610A instrument is EN60825 Class II –1 mW certified for Laser Safety. 
• Do not use any damaged part. 
•  Do not operate instrument in an explosive atmosphere. It is recommended 

that you read the safety and operation instructions before using the infrared 
thermometer. The symbol on the instrument indicates that the operator must 
refer to an explanation in this manual.

DANGER

Pressing the button that turns the laser marker on and off. Exercise extreme care and 
do not allow the laser beam to enter your eye or those of any other person or animal. 
• Do not look directly into the laser light. 
•  When measuring the temperature of an object which has a mirror finish, be 

careful not to allow the laser light beam to be reflected off the surface into your 
eyes or those of another person. 

•  Do not allow the laser light beam to impinge upon any object or gas which can 

explode.

CAUTION

•  Do not use the unit near any device which generates strong electromagnetic 

radiation or near a static electrical charge, as these may cause errors.

•  Do not keep or use this unit in an environment where it will be directly illuminated 

by sunshine, or where it will be exposed to high temperatures, high humidity or 
condensation. If you do, it may be deformed, its insulation may be damaged, or it 
may no longer function according to specification due to sensor damage.

•  Do not contact the lens against the object whose temperature is to be measured, 

or get it dirty, allow it to be scratched, or allow any foreign material to adhere 
to it. Doing so may cause errors.

•  Do not touch or hold by the front cone. Temperature reading can be affected by 

heat from hand.

•  If the meter is exposed to significant changes in ambient temperature (hot to 

cold or cold to hot). Allow 20 minutes for temperature stabilization, before 
taking measurement.

•  Condensation may form on the lens when going from a cold to hot environment. 

Wait 10 minutes for condensation to dissipate before taking measurements.

•  This unit is not constructed to be water proof or dustproof, so do not use it in a 

very dusty or wet environment.

INTRODUCTION

The IR610A is a portable easy use 3½ digit, compact- sized digital Infrared 
thermometer capable of measuring °C and °F temperature. Its controls are:  
1. Sighting Laser On/Off button. 2. °C/°F selector. 3. LCD Backlight On/Off button. 
4. mV Output jack. 5. LCD Display. 6. Measure button. 7. Laser output and 
Thermopile input lens.

H

0

0

F

+ -

0

C

0

F

3

2

1

6

7

5

4

IR610A

THERMOMETER

8

 

 

 

 

 

 

Amprobe® Test Tools Europe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
*(Correspondence only – no repair or replacement available from this address. 
European customers please contact your distributor.)

SPECIFICATIONS

General Specifications
Display: 3½ digit (LCD) with maximum reading of 1999
Overrange: (OL) or (-OL) is displayed
Low battery indication: “ 

 “. Change batteries immediately.

Measurement rate: 2.5 times per second, nominal.
Operating Environment: 0 °C to 50 °C (32 °F to 122 °F) at < 75% R.H.
Storage Temperature: -20 °C to 60 °C (-4 °F to 140 °F), 0 to 80 % R.H. with batteries 
removed
Environment: Indoor use, Altitude up to 2000 m.
Battery: 4 pcs 1.5V (AAA size) UM-4, R03
Battery Life: 100 hours carbon-zinc battery
Auto power off: approximately 15 seconds
Standby current: <8 μA
Dimensions: 170 x 44 x 40 mm
Weight: 160g including batteries
EMC: Conforms to EN61326-1. This product complies with requirements of the 
following

 European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) 

as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense 
electromagnetic fields in the vicinity of the equipment may disturb the 
measurement circuit. Measuring instruments will also respond to unwanted 
signals that may be present within the measurement circuit. Users should exercise 
care and take appropriate precautions to avoid misleading results when making 
measurements in the presence of electronic interference.

Operational Specifications
Accuracy: at 23°C ± 5°C (73°F ± 9°F), < 75 % relative humidity
Temperature Range: - 20 °C to 260 °C; 0 °F to 500 °F
Display Resolution: 1 °C; 1 °F
Accuracy: ± 3% of reading or ± 3 °C / ± 6 °F, whichever is greater @ 18 to 28°C 
ambient.
Temperature Coefficient: ± 0.2 % of reading or ± 0.2 °C, whichever is greater, per °C, >
28°C or < 18°C
Response Time: 0.4 second
Spectral Response: 6 to 14μm nominal
Emissivity: Pre-set 0.95
Detection Element: Thermopile
Optical Lens: Fresnal Lens
Field of View: 100 mm Ø at 1000 mm
Sighting: 1 - Laser beam marker < 1 mW (670nm) Class 2
Analog output: 1 mV / °C or 1mV / °F , nominal, continuous output

EXPLANATION OF SYMBOLS

Laser Beam - Do not stare into Laser
beam or direct it toward the eyes.

Содержание AMPROBE IR610A

Страница 1: ...do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you CERTIFICATIONS AND PRECAUTIONS The IR610A instrument is EN60825 Class II 1 mW certified for Laser Safety Do not use any damaged part Do not operate instrument in an explosive atmosphere It is recommended that you read the safety and operation i...

Страница 2: ... ne s appliquent pas à votre cas CERTIFICATIONS ET PRECAUTIONS L instrument IR610A est certifié conforme à EN60825 classe II 1 mW pour la sécurité laser Ne pas utiliser de pièce endommagée Ne pas utiliser l appareil dans une atmosphère explosive Il est recommandé de lire les consignes de fonctionnement et de sécurité avant d utiliser le thermomètre infrarouge Le symbole sur l appareil indique que ...

Страница 3: ...ulassen ist diese Gewährleistungsbeschränkung möglicherweise für Sie nicht gültig ZERTIFIZIERUNGEN UND SICHERHEITSHINWEISE Das IR610A Messgerät ist nach EN60825 Klasse II bis 1 mW für Lasersicherheit zertifiziert Keine beschädigten Teile verwenden Das Messgerät nicht in Umgebungen mit explosiven Gasen betreiben Bediener sollten vor Gebrauch des Infrarotthermometers die Sicherheits und Bedienungsan...

Страница 4: ...N60825 Classe II 1 mW certificato in relazione alla sicurezza laser Non usare alcun componente danneggiato Non usare lo strumento in un atmosfera esplosiva Si suggerisce di leggere le istruzioni per l uso e la sicurezza prima di usare lo strumento L apposito simbolo sullo strumento rimanda a una spiegazione nel presente manuale PERICOLO Quando si preme il pulsante che accende il laser fare estrema...

Страница 5: ...es esta limitación de responsabilidad puede no regir para usted CERTIFICACIONES Y PRECAUCIONES El instrumento IR610A está certificado según EN60825 Clase II 1 mW para seguridad láser No lo utilice si existe alguna pieza averiada No encienda el instrumento en una atmósfera explosiva Se recomienda que lea las instrucciones de seguridad y operación antes de utilizar el termómetro infrarrojo El símbol...

Страница 6: ...dor så denna ansvarsbegränsning gäller eventuellt inte dig GODKÄNNANDEN OCH FÖRSIKTIGHETSÅTGÄRDER IR610A instrumentet är EN60825 klass II 1 mW godkänt för lasersäkerhet Använd inga skadade delar Använd inte instrumentet i en miljö där explosionsrisk föreligger Vi rekommenderar att du läser säkerhets och bruksanvisningarna innan du använder den infraröda termometern Symbolen på instrumentet indiker...

Отзывы: