![PESA Cheetah 1024x256 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/pesa/cheetah-1024x256/cheetah-1024x256_manual_1531780135.webp)
C
HEETAH
S
ERIES
S
WITCHERS
–
C
HAPTER
9
81-9059-0570-0
Rev. C
Proprietary Information of
PESA
S
WITCHING
S
YSTEMS
,
I
NC
.
120
Chapter 9:
Cable Installation and
Power Connections
9.1
C
ONNECTING
E
QUIPMENT
C
ABLES
Use the following guidelines when connecting equipment cables:
1.
Install the equipment in the rack before connecting cables.
Relieve strain on all cables to prevent connector separation.
To the extent possible, separate control, signal, and power cables to minimize crosstalk and
interference.
Use as many cable ties as necessary to secure cables to the rack (see Figure 49). This will minimize
the amount of force transmitted to the equipment and help route cables away from hazardous
areas.
FIGURE 49: Cables Attached To Supports
Route cables away from physical traffic areas to avoid creating a safety hazard (trip or shock).
Bundle together any cables connected to a single input/output card and separate them from the other
bundles with enough slack to create a service loop. This will permit individual card replacement
without disruption to the other input/output cards.
Содержание Cheetah 1024x256