Konstruktion
:
6.
Maintenance
Protection
The
controller
is
protected
by
a
sensitive
T
0,2
AH
250
V
fuse.
The
most
common
cause
of
a
blown
fuse
is
a
short
‐
circuited
control
cable
of
a
valve.
A
short
circuit
is
briefly
indicated
by
a
check
on
the
screen.
Then
the
display
switches
off
completely
and
all
messages
disappear.
Replace
Fuse
8.
Unplug
the
controller
from
the
mains.
9.
Remove
the
front
cover
by
unscrewing
its
screws.
The
fuse
is
located
on
the
right,
above
the
terminals
for
the
power
supply
cable
(see
chapter
5
–Controller)
10.
Remove
the
faulty
fuse
from
the
holder.
11.
Install
a
new
fuse.
12.
Replace
the
front
cover.
13.
Plug
the
power
supply
cable
unit
into
the
mains.
14.
Check
proper
function
of
the
controller.
WARNING
The
controller
is
protected
by
a
0.2AH
(slow)
fuse.
Any
attempt
to
bridge
(bypass)
the
fuse
or
to
replace
it
with
a
different
type
may
result
in
serious
injuries
and/or
damage
to
the
unit.
Increase
Number
of
Stations
to
be
Controlled
by
the
Controller
Factory
setting
of
controller
(SG49152)
=
4
stations
(equals
2
Sector
Scout
stations)
Should
you
need
to
increase
the
existing
number
of
stations,
you
can
do
so
in
steps
of
4
stations
up
to
a
maximum
of
24
stations.
Order
the
required
number
of
additional
output
modules
No.
SB49112
from
your
local
supplier.
Each
module
comprises
4
stations.