Konstruktion
:
Connect
VP3
with
Sector
Scout
as
per
wiring
scheme
on
page
7.
Please
note
that
in
this
case
only
2
stations
per
module
can
be
connected.
Change
entries
in
the
controller
software
as
follows:
Channel
A:
wired
with
solenoid
and
Channel
B:
wired
with
position
sensor
Please
proceed
as
follows:
Press
and
to
select
„Module
setup“
and
press
to
confirm.
Press
and
to
select
a
station
where
a
VP3
with
Sector
Scout
is
supposed
to
be
connected.
Use
to
set
the
selected
station
to
„SC
output“.
Warning
If
both,
stations
with
Sector
Scout
(VP3SC)
and
stations
with
valves
only,
are
connected
to
the
same
controller,
all
stations
with
Sector
Scout
have
to
be
connected
in
consecutive
order
starting
from
module
1.
The
valves
(no
Sector
Scout)
can
then
be
connected
to
the
remaining
modules
regardless
of
their
order.
press
to
confirm
entry.
To
get
back
to
the
„Sector
Scout“
menu,
press
„previous
menu“.