Cleaning Nozzle Parts
1 Unscrew pressure cap from top of each nozzle assembly
2 Clean or replace diaphragm
3 Unscrew nozzle caps to remove strainer screen, nozzle tip and gasket
4 Examine parts and either clean by running under water, or replace as needed
5 Reinstall nozzle assemblies
TOOLS
none
© 2004 Perma Green Supreme, Inc. All rights reserved.
DOCUMENT ID: U005M
1 With 7/16” socket or 7/16” wrench, remove the (4) tank bolts. If the tank threads strip out,
use a pry bar to force the tank loose
2 Remove 3/8” clear hose from back of tank
3 Remove the (2) hose clamps and then remove the 1/4” braided hose
4 Remove tank
5 Set new tank in place
6 Reinstall in the (4) tank bolts
7 Reconnect all hoses
Replacing Weed Control Tank
TOOLS
7/16” socket
7/16” wrench
Pliers
page