Column Refrigeration Service Manual
96
Operation #5
THE FOLLOWING STEPS ARE
TO REPLACE THE GAS SPRING
AND DAMPER ONLY. SKIP TO
OPERATION #6 FOR TIP-OUT
BIN ASSEMBLY.
1.
Locate the end fitting on the gas spring on the left
side of the bin and using the flat head screwdriver,
release the end fitting by placing the flat head
screwdriver into the release latch and prying
outward to disengage the end fitting from the bin
wall ball stud.
2.
Locate the damper end fitting on the right side of
the cabinet. Using a flat head screwdriver, release
the end fitting on the damper, by placing the flat
head screwdriver into the release latch and prying
inward to disengage the end fitting from the bin
ball stud.
3.
Once removed, press & snap the new gas spring or
damper back onto the ball stud.