![Perlick CC24D Series Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/perlick/cc24d-series/cc24d-series_service-manual_1530930080.webp)
Column Refrigeration Service Manual
80
8.7 Activation/Deactivation of Hinges
Pinch hazard! Always de-activate hinges before
removing from door and cabinet.
To activate the self-closing feature of the hinge
follow these steps:
1) Open the door to expose the T-20 torx fastener
in the obround hole in the hinge labeled
position zero (0) and one (1).
2) Using a T-20 torx drive, turn the fastener
approximately 9 to 9-1/2 turns from the zero
(0) position to the one (1) position. Do not
over-tighten (2Nm torque max).
To de-activate the hinges move the T-20 torx
fastener from position one (1) to position zero
(0) by turning the fastener 9 to 9-1/2 turns
(see figures 8-7.1 and 8-7.2 for activated and
deactivated positions).
CAUTION
Figure 8-7.1. Hinge activation fastener
(shown in de-activated position).
Figure 8-7.2. Hinge activation fastener
(T-20) (shown fully activated).