Column Refrigeration Service Manual
45
STEP 3 - Refrigeration Module Gasket
A gasket is used to seal between the refrigeration
module and the bottom of the cabinet.
See Figure
6-2.1.
Ensure refrigeration module is lifted tight against
the bottom of the cabinet using the refrigeration
module lift kit (lift bolts should be tight against
face of left and right cabinet machine compartment
endplates).
See Figure 6-2.2.
Check for condensation or cold air around the top
perimeter of the refrigeration module, or using a
bright light, shine the light at the gasket and look
for light on the other side of the gasket. If any
condensation, cold air or light can be detected
around the gasket, remove the refrigeration module
and inspect the gasket and replace. See section
Replace Refrigeration Module for details on how to
remove the module.
STEP 4 - Drain
Check that the evaporator condensate drain is
secure and connected.
See Figure 6-3.
Figure 6-2.1. Refrigeration Gasket
Figure 6-2.2. Lift Bolts
Figure 6-3. Evaporator Condensate Drain