![Perlick CC24D Series Скачать руководство пользователя страница 106](http://html.mh-extra.com/html/perlick/cc24d-series/cc24d-series_service-manual_1530930106.webp)
Column Refrigeration Service Manual
106
8.17 Dual-Zone Wine
Compartment Divider
Removal
To remove the dual zone wine compartment
divider, locate the two fasteners on the bottom left
and right edges and remove. Pull out on the divider
and disconnect the light electrical connector.
Remove divider from the cabinet.
Installation
To install, slide divider into cabinet extrusions,
make light electrical connection, manage excess
wire and push divider into cabinet until flush with
back wall. Install retaining fasteners into bottom
left and right edges.
Figure 8-20.1. Dual-Zone Compartment Divider
Figure 8-20.2. Dual-Zone Compartment Divider