Air filter
Environmental conditions have an important effect on the frequency at which the air filter needs service.
The filter element must be cleaned or renewed according to the manufacturer's recommendations.
Restriction indicator
The restriction indicator for these engines must work at a pressure difference of 635 mm (25 in) of water gauge.
It is fitted on the air filter outlet or between the air filter and the induction manifold.
The restriction indicator should be tested according to the manufacturer's recommendations.