RCS-2 Climbing Device and Hydraulics
Assembly Instructions
C3 Maintenance
Maintenance and repairs
■
Damage and any resulting downtime
can be avoided by carrying out
scheduled maintenance work.
■
Refer to the maintenance table of
the manufacturer for the hydraulic
unit maintenance intervals.
PERI recommends shortened mainte-
nance intervals:
■
for equipment showing signs of
heavy wear.
■
with high thermal and mechanical
loads.
■
when subject to heavy soiling.
Maintenance and repairs
Recommended maintenance inter-
vals
■
Replace oil filter, air filter and hydraulic oil.
Before use on next construction site,
minimum 1x yearly.
■
Replace hydraulic hoses.
If case of damage, before use on next
construction site.
Maximum service life 6 years.
■
Check oil temperature and oil level.
Before use on next construction site.
■
Clean machine housing and cylinder.
■
Lubricate moving parts on the cylinder.
If necessary,
after each concreting process.
■
Check system for leaks.
■
Check working and control pressures.
■
Check system for noises and vibrations.
■
Check hoses for external damage.
After assembly.
Daily to weekly.
■
Lubricate Climbing Rail RCS.
If necessary,
weekly to monthly.
■
Check device mounting.
Weekly to monthly.
■
Check housing (dirt, damage, protective
covers)
■
Check performance.
Monthly to quarterly.
■
Check tubes and hoses.
■
Check protective covers.
Before first use, every six months to
one year.
■
Maintenance work on the hydraulic unit.
See manufacturer’s assembly instruc-
tions.