24
RCS-2 Climbing Device and Hydraulics
Assembly Instructions
C1 Initial commissioning
■
Data connections may only be estab-
lished in a de-energised state.
■
Data connections between climbing
groups can be established with
Data Connection RCS MAX wireless
instead of with Data Connecting Ca-
bles RCS MAX.
■
The Remote Control RCS MAX wire-
less can be used as a remote control
instead of the Remote Con-
trol RCS MAX 15m.
Measures prior to initial commis-
sioning
■
Check the completeness of the tech-
nical documentation, e.g. hydraulic
connection diagram, electronics con-
nection diagram, data cable connec-
tion diagram, manufacturer’s assem-
bly instructions.
■
Site personnel to familiarise them-
selves with the equipment using the
available documentation.
■
Clean the bushings and clips of all
quick-couplers prior to coupling and
check for damage.
■
For more commissioning details, see
the manufacturer’s assembly instruc-
tions.
Power Cable RCS MAX 2m
Danger
Significant electrical voltage during op-
eration!
Death or serious injury can result from
an electric shock.
⇒
Only qualified electricians may carry
out work and repairs on the electrical
components of the system.
■
If it is not possible to use the Pow-
er Cable RCS MAX CEE-32A 2m, a
country-specific connector can be fit-
ted onto the Power Ca-
ble RCS MAX 2m (
22
).
■
Refer to the manufacturer’s assem-
bly instructions for the terminal allo-
cation diagram.
Standard assembly
1. Assemble or set up the pump, see
Section E1 “Connection diagram”.
2. Connect the hydraulic hoses.
3. Check the oil level of the pump, and
fill if necessary.
4. Attach the data connection cable.
5. Attach the power connection cable.
6. Connect remote control.
7. Attach the connection cable.
8. Seal unused connections with mat-
ing plugs and cover caps.
9. Check all fastenings and connec-
tions.
10. Power on the system and check the
rotary field on the keypad, see sec-
tion D4 “Climbing procedure”.
11. Set the hydraulic cylinder down on
the platform for venting.
12. Ventilate system and check for leak-
age, see Section D7 “Remedial
measures for malfunctions” and the
manufacturer’s installation instruc-
tions.
13. Carry out any additional steps in the
manufacturer’s assembly instruc-
tions.
14. Install hydraulic cylinder.
15. Put the system into operation.
22